Warnings

Warnings

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING

FIRE

FIRE

FIRE AND

AND

AND EXPLOSION

EXPLOSION

EXPLOSION HAZARD

HAZARD

HAZARD

Flammable fumes, such as solvent and paint fumes, in work

work

work area

area

area can ignite or explode. Paint

or solvent flowing through the equipment can cause static sparking. To help prevent fire and
explosion:

• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static sparking).

• Ground all equipment in the work area. See Grounding

Grounding

Grounding instructions.

• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable

fumes are present.

• Use only grounded hoses.
• Stop

Stop

Stop operation

operation

operation immediately

immediately

immediately if static sparking occurs or you feel a shock. Do not use

equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

SPECIAL

SPECIAL

SPECIAL CONDITIONS

CONDITIONS

CONDITIONS FOR

FOR

FOR SAFE

SAFE

SAFE USE

USE

USE

Equipment must comply with the following conditions to avoid hazardous condition which
can cause fire or explosion:

• Clean plastic parts only in well ventilated area.

• Do not clean with a dry cloth.

PRESSURIZED

PRESSURIZED

PRESSURIZED EQUIPMENT

EQUIPMENT

EQUIPMENT HAZARD

HAZARD

HAZARD

Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.

• Follow the Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure when you stop spraying/dispensing and before

cleaning, checking, or servicing equipment.

• Tighten all fluid connections before operating the equipment.
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

3A5400B

3

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Summary of Contents for SaniForce SPU.A01AAA1AA0C21

Page 1: ...ional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual and in manuals...

Page 2: ...ls Models Model Model Model Certification Certification Certification Approvals Approvals Approvals SPU A01AAA1AA0C21 EN 10204 type 2 1 SPU A01AAA1AA0C31 EN 10204 type 3 1 II 2 GD Ex h IIA T4 Gb X Ex...

Page 3: ...d gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Stop Stop Stop operation operation operation immediately...

Page 4: ...quest Safety Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in us...

Page 5: ...OTE Some combinations are not possible Please check with your local supplier Sanitary Sanitary Sanitary Pail Pail Pail Unloader Unloader Unloader Frame Frame Frame Pump Pump Pump Platen Platen Platen...

Page 6: ...flat and that the unit doesn t wobble NOTE NOTE NOTE If the unit is being located in a permanent location use the four holes in the baseplate as a guide to locate where to drill holes for mounting an...

Page 7: ...Locate upstream from all other air line accessories Air Air Air relief relief relief valve valve valve 100 100 100 psi psi psi two attached to ram integrated air controls for pump and ram air not vis...

Page 8: ...handle to the neutral center position 2 Place a full pail on the base and center it under the Platen D 3 Adjust the pail to be sure it is aligned with the platen and open the platen bleed port J NOTE...

Page 9: ...he pail to push it off of the platen c When the platen is free of the pail and the ram reaches its full height move the director valve handle BD to the neutral position 3 Remove the empty pail 4 Inspe...

Page 10: ...ng equipment Flush at the lowest pressure possible Check connectors for leaks and tighten as necessary Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted par...

Page 11: ...from the pump lower unit continue raising the ram until the lower unit clears the platen Move the ram director valve BD handle to neutral to stop raising the ram 6 Slide the platen out from under the...

Page 12: ...s A In mm B In mm C In mm D In mm E In mm F In mm G In mm 62 82 1596 42 34 1075 6 0 152 24 82 630 12 0 305 22 0 559 10 0 254 12 3A5400B Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www...

Page 13: ...ure 120 F 49 C Fluid Fluid Fluid Outlet Outlet Outlet Size Size Size Stainless Steel 1 5 in Sanitary Flange Weight Weight Weight Stainless Steel approximately 160 lb approximately 72 6 kg Wetted Wette...

Page 14: ...LAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PART...

Reviews: