background image

Operation

Change

Change

Change Pail

Pail

Pail

1.

Turn off pump air supply by pushing the air motor
slider valve (BH) to the off position.

2.

Raise the platen out of the pail:

NOTE:

NOTE:

NOTE: When raising the ram, the pail must be
pushed off of the platen by use of the blowoff
button (BG). When the blowoff button (BG) is
pushed, the air supply raising the ram is diverted
to the blowoff connection on the platen and
creates a pressure to push the pail off of the
platen. If the ram director valve (BD) is not in the
up (raise ram) position, the blowoff button (BG)
has no functionality.

a.

Move the director valve handle (BD) to the
UP position.

b.

As the ram raises the pail off of the base,
periodically press the blowoff button (BG) to
create a pressure in the pail to push it off of
the platen.

c.

When the platen is free of the pail and the
ram reaches its full height, move the director
valve handle (BD) to the neutral position.

3.

Remove the empty pail.

4.

Inspect platen and, if necessary, remove
any remaining material or material
build-up. If full cleaning is necessary, see

Cleaning the Platen, page 11

.

5.

To empty another pail, perform the steps of

Start and Adjust Ram, page 8

.

Pump

Pump

Pump Shutdown

Shutdown

Shutdown

At the end of the work shift, after any
necessary flushing, and before you check,
clean, adjust, or repair the system, follow the

Pressure Relief Procedure, page 8

Always stop the

pump at the bottom of its stroke to prevent fluid from
drying on the displacement rod. (The air motor will
exhaust at the bottom or top of the stroke.)

Turn off the air supply shutoff valve (W).

3A5400B

9

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Summary of Contents for SaniForce SPU.A01AAA1AA0C21

Page 1: ...ional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual and in manuals...

Page 2: ...ls Models Model Model Model Certification Certification Certification Approvals Approvals Approvals SPU A01AAA1AA0C21 EN 10204 type 2 1 SPU A01AAA1AA0C31 EN 10204 type 3 1 II 2 GD Ex h IIA T4 Gb X Ex...

Page 3: ...d gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Stop Stop Stop operation operation operation immediately...

Page 4: ...quest Safety Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in us...

Page 5: ...OTE Some combinations are not possible Please check with your local supplier Sanitary Sanitary Sanitary Pail Pail Pail Unloader Unloader Unloader Frame Frame Frame Pump Pump Pump Platen Platen Platen...

Page 6: ...flat and that the unit doesn t wobble NOTE NOTE NOTE If the unit is being located in a permanent location use the four holes in the baseplate as a guide to locate where to drill holes for mounting an...

Page 7: ...Locate upstream from all other air line accessories Air Air Air relief relief relief valve valve valve 100 100 100 psi psi psi two attached to ram integrated air controls for pump and ram air not vis...

Page 8: ...handle to the neutral center position 2 Place a full pail on the base and center it under the Platen D 3 Adjust the pail to be sure it is aligned with the platen and open the platen bleed port J NOTE...

Page 9: ...he pail to push it off of the platen c When the platen is free of the pail and the ram reaches its full height move the director valve handle BD to the neutral position 3 Remove the empty pail 4 Inspe...

Page 10: ...ng equipment Flush at the lowest pressure possible Check connectors for leaks and tighten as necessary Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted par...

Page 11: ...from the pump lower unit continue raising the ram until the lower unit clears the platen Move the ram director valve BD handle to neutral to stop raising the ram 6 Slide the platen out from under the...

Page 12: ...s A In mm B In mm C In mm D In mm E In mm F In mm G In mm 62 82 1596 42 34 1075 6 0 152 24 82 630 12 0 305 22 0 559 10 0 254 12 3A5400B Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www...

Page 13: ...ure 120 F 49 C Fluid Fluid Fluid Outlet Outlet Outlet Size Size Size Stainless Steel 1 5 in Sanitary Flange Weight Weight Weight Stainless Steel approximately 160 lb approximately 72 6 kg Wetted Wette...

Page 14: ...LAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PART...

Reviews: