Replace Fluid Inlet Sensor
Note
For Elite models only.
1. Perform
.
2. Perform
Pressure Relief Procedure, page 42
.
3. Disconnect inlet sensor cable from the fluid inlet
assembly. Inspect cable for damage and replace
if necessary. See
Electrical Schematics, page 89
.
Figure 9 Fluid Inlet Sensor
4. To replace sensor cable:
a. Open wire bundle and remove sensor cable.
b. Cut any wire ties and disconnect from MCM.
See
Electrical Schematics, page 89
NOTICE
To prevent damage to cable, route and secure
cable in wire bundle with wire ties.
5. Replace sensor (602).
Replace Pressure Transducers
1. Perform
.
2. Perform
Pressure Relief Procedure, page 42
3. Disconnect transducer cables (405) from #6 and
#7 connectors on the MCM.
4. Remove wire ties constraining transducer cable
and remove cable from cabinet.
5. Install o-ring (416) on new transducer (405).
6. Install transducer in manifold. Mark end of cable
with tape (red=transducer A, blue=transducer B).
7. Route new cable into cabinet and thread into
bundle as before. Attach cable ties to bundle
as before.
8. Connect A side pressure transducer cable
to MCM port #6. Connect B side pressure
transducer cable to MCM port #7.
405
416
405
401
333024A
55