Replace Motor Control Module (MCM)
1. Perform
2. Disconnect connectors from MCM (63).
Disconnect two power cables. See
Electrical Schematics, page 89
.
3. Remove nuts (91) and MCM (63).
4. Set rotary switch. 2= E–30 and 3= E-XP2.
5. Replace MCM in enclosure.
6. Connect cables to MCM. See
Electrical Schematics, page 89
.
Figure 22 Replace MCM
Replace Temperature Control Module
(TCM)
1. Perform
.
2. Open electrical enclosure door (61).
3. Disconnect all connectors from the TCM (403).
4. Remove four nuts (411) and TCM (403).
5. Install new TCM module (403). Reassemble
parts in reverse order.
Figure 23 Replace TCM
68