Operator Controls
◆
EasyKey™ Display
310633C
29
Printer Port
The serial printer port (RS-232) is used with optional
Printer Kit 234670, which enables you to print individual
job tickets after each dispense transaction is complete.
See page 43. Refer to printer manual 308818 for addi-
tional information.
Graco PC Cable Port
The Graco PC Cable Port is for use with the ProMix™ II
Data Download Kit 234668, which enables you to com-
municate with the ProMix™ II from a PC to:
➜
Upgrade software
➜
View software version
➜
Download
•
job and alarm logs
•
material usage report
•
setup values (can also upload)
➜
Clear job, alarm, and material usage reports
➜
Upload a custom language to view on screen
➜
Restore factory defaults
➜
Restore setup password
See Data Download manual 310669 or ProMix™ II Ser-
vice manual 310653 for more information.
Ethernet Connection
You can access data from the ProMix™ II on an office or
industrial network or through the internet with the proper
network configuration. You will need an external module,
commonly called an Ethernet to Serial Converter, that
converts serial data (RS-232) to ethernet.
Converters are available from electronics suppliers such
as B&B Electronics and Omega.
Wire the serial to ethernet converter on the EasyKey™
control board as follows.
Some converters are powered by 24 VDC power
and are DIN rail mounted. Do not power any exter-
nal device using the ProMix™ II power supply; an
external power supply must be used.
!
IMPORTANT: Once modifications are made to the
ProMix™ II electronics, the electrical approvals
may no longer apply. Contact your Graco distributor
for details
Connection
Function
J6-1
RS-232 Transmit
J6-2
RS-232 Receive
J6-3
RS-232 Ground
Summary of Contents for ProMix II
Page 5: ...Related Manuals 310633C 5 ...