Alarm Troubleshooting
◆
ProMix™ II Alarms
52
310633C
Communication Error Alarm (E1)
Cause
Solution
•
The communication signal between the EasyKey™
Display, Smart Fluid Panel, or Operator Station was
interrupted.
•
Verify that all cables are correctly connected. See
Cable Connections, page 20.
•
The fiber optic cable is cut or bent.
•
Verify cables have not been cut or bent at a radius
smaller than 1.6 in. (40 mm).
•
Dirty fiber optic cable ends
•
Disconnect fiber optic cable ends and clean with a
lint-free cloth.
•
A communication cable or connector failed.
•
Replace cable.
Purge Error (E2) Alarm
Cause
Solution
•
ProMix™ II detects atomizing air flow to the gun dur-
ing Purge or Color Change sequence.
•
Verify that the gun air is shut off and atomizing air
safety valve is connected and functioning.
•
In systems with a gun flush box, operator selects to
Purge or Color Change when the gun is not in the
gun flush box.
In systems set up for Autodump (page 36),
Autodump is initiated when gun is not in the gun
flush box.
•
Verify that the gun is in the gun flush box and the
door is fully closed. For additional Gun Flush Box
information, see manual 310695.
To abort a Color Change or Purge:
Press Standby
, then Error Clear
keys to clear alarm.
CAUTION
The material may have cured in the system. Always
place the gun in the gun flush box when the gun is not
in use.