ProMix™ II Models
◆
310633C
3
ProMix™ II Models
WARNING
Do not install equipment approved only for a non-haz-
ardous location in a hazardous area. Substitution of
components may impair intrinsic safety. See page 6.
WARNING
Changing the fluid manifold configuration may change
its pressure rating. Do not exceed the pressure rating
of the lowest rated component. See page 6.
PM
Enter Model number here
ProMix™ II
Unit
A Meter
B Meter
Color Change
Gun Flush
Box
PM
0
None
0
None
0
None, Single Color
0
No
1
G3000
1
G3000
1
2 Color, Low Pressure
1
Yes
2
G3000HR
2
G3000HR
2
4 Color, Low Pressure
3
Coriolis
3
Coriolis
3
6 Color, Low Pressure
4
2 Color, High Pressure
5
4 Color, High Pressure
6
6 Color, High Pressure
Hazardous Location Approval
Only models with a G3000 (1) or G3000HR (2) for both A and
B meters are approved for installation in a Hazardous Loca-
tion - Class I, Div I, Group D, T3.
Non-hazardous Location Approval
Maximum Working Pressure
Maximum working pressure rating is dependent on the A and B meter and color change option selected. The pres-
sure rating is based on the rating of the lowest rated fluid manifold component. Refer to the component pressure
ratings below. Example: Model PM1140 has a maximum working pressure of 3000 psi (21 MPa, 207 bar).
Check the ID plate on your EasyKey™ Display or fluid panel for its maximum working pressure. See F
page 15.
ProMix™ II Fluid Manifold Components Maximum Working Pressure
Color Change Option 1, 2, or 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (2.1 MPa, 21 bar)
Color Change Option 4, 5, or 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 psi (21 MPa, 207 bar)
Coriolis A and B Meters Option 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2300 psi (16 MPa, 159 bar)
No Meters or G3000 or G3000HR A and B Meters Option 0, 1, or 2 . . . . . . . . . . . . . . . 4000 psi (28 MPa, 276 bar)
Flow Meter Fluid Flow Rate Range
G3000 Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75-3000 cc/min. (0.02-0.79 gal./min.)
G3000HR Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-1500 cc/min. (0.01-0.40 gal./min.)
Coriolis Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-3800 cc/min. (0.005-1.00 gal./min.)
#
53
Conforms to FM std 3600 & 3610
for use in Class I Div 1 Group D T3
Hazardous locations
CAN/CSA 22.2 No. 157 & 1010.1-92
EEx ib IIA T3
ISSeP 04 ATEX 008
SYST
#
53
CAN/CSA
22.2 No. 1010.1
Summary of Contents for ProMix II