Description

334371A

3

Description

P is an electrically operated protective device that monitors the supply voltage to 

Graco electrical equipment. If there are excessive voltage fluctuations (high or low) P 

disconnects the equipment from the power source to reduce the risk of damage to the 

equipment. P automatically resets after a one minute delay when acceptable power 

is available.

Operation of the P is indicated by a multi-color LED.

The power cord includes a ground wire with an appropriate ground contact. Do not use 

P if the electrical cord has a damaged ground contact. The cord must be plugged 

into an outlet that is properly installed and grounded in accordance with all local codes and 

ordinances.

LED

Definition

LED is ON

When the LED is solid green the P is powered and 
in normal operation.

LED is BLINKING 

When the LED blinks red the supply voltage is too low or too 
high for the equipment and will not run until it is plugged into a 
good power supply. 

LED is OFF

No power to P. 

ti24427a

Multi-Color LED

ti24517a

ti24533a

ti24518a

ti24534a

Summary of Contents for ProGuard+

Page 1: ...ainst voltage fluctuations Model 24W090 24W755 24W755 230V IEC 320 24W090 230V CEE 7 7 Shuko Important Safety Instructions Read all warnings and instructions in this manual Be familiar with the contro...

Page 2: ...not completely understood or when in doubt as to whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified...

Page 3: ...ulti color LED The power cord includes a ground wire with an appropriate ground contact Do not use ProGuard if the electrical cord has a damaged ground contact The cord must be plugged into an outlet...

Page 4: ...er than the rated voltage of the equipment Locate a power source that supplies the correct voltage Low Voltage Typically caused when other equipment is on the same circuit or when operating on generat...

Page 5: ...10Amps High Voltage Disconnect 280VAC Low Voltage Disconnect 170VAC Reset Time 60 seconds Weight 400g 0 9 lbs Dimensions 150 x 50 x 45 mm 6 0 x 2 0 x 1 75 in Operating temperature range 34 to 46 C 30...

Page 6: ...s of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS...