background image

Installation

Main Air Line

Fluid Line

A

B

C

D

E

F

KEY

A

Air Exhaust Muffler (may alternately be
mounted remotely, using exhaust hose)

B

3/4 npt Exhaust Air Outlet

C

Air Line Filter/Regulator

D

Bleed-Type Master Air Valve 

(required)

E

Air Solenoid Valve

F

3/8 npt Air Inlet

G

Air Line Drain Pipe and Valve

H

1–1/2” Tube Size Flanged Fluid Outlet

J

Dispensing Valve

K

Timer Control

L

Air Regulator

M

Bung-Mounted Sanitary Pump

N

Dispensing Valve Air Exhaust Hose

P

Sensing Device

Y

Pump Ground Wire

 (required; see page

4  for installation instructions)

G

J

K

H

L

0591

D

E

D

G

M

N

Y

P

0.5” (13 mm) clearance

Fig. 2

System Accessories

Install a bleed-type master air valve (D) close to the
pump air inlet (F), to relieve air trapped between it and
the air motor.

WARNING

The bleed-type master air valve (D) is required in
your system to shut off and relieve air pressure that
may be trapped in the air motor. This air could
cause the pump to cycle unexpectedly, which could
result in serious injury, including amputation or
splashing of fluid in the eyes or on the skin.

Install an air filter/regulator (C) in the pump air line,
upstream from the bleed valve, to control air inlet
pressure and to remove harmful dirt and contaminants
from your compressed air supply.

Install another bleed-type master air valve (D) up-
stream from all air line accessories and use it to isolate
the accessories during cleaning and repair.

On the air drop to the dispensing valve (J), install an
air regulator (L) to control air pressure to the valve.
Install a bleed valve (D) to use as a shutoff when
servicing the dispensing valve.

Connect air solenoid valves (E) to a timer control (K),
and set so the dispensing valve (J) will dispense at
proper intervals.

Connect the Hoses

Connect electrically conductive air supply hoses to the
air inlets of the pump and dispensing valve.

Connect the fluid line between the pump’s 1–1/2”
flanged fluid outlet and the fluid inlet of the dispensing
valve.

NOTE: 

Be sure to install  the complete system in

accordance with all state sanitary standard codes and
local regulations.

Summary of Contents for Monark 207550

Page 1: ...id Working Pressure 120 psi 8 bar Maximum Air Input Pressure Model 207 550 Series E 55 gallon 200 liter drum size Table of Contents Symbols 2 Safety Warnings 2 Installation 4 Operation 6 Maintenance 7...

Page 2: ...t alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not exceed the maximum working pressure of the lowest rated system component Refer to...

Page 3: ...a Do not smoke in the dispense area Do not turn on or off any light switch in the dispense area while operating or if fumes are present Do not operate a gasoline engine in the dispense area TOXIC FLUI...

Page 4: ...rs and letters in parentheses in the text refer to the callouts in the figures and the parts drawing NOTE Always use Genuine Graco Parts and Acces sories available from your Graco distributor Refer to...

Page 5: ...le unexpectedly which could result in serious injury including amputation or splashing of fluid in the eyes or on the skin Install an air filter regulator C in the pump air line upstream from the blee...

Page 6: ...the bleed type master air valve D Adjust the pump air regulator C until the pump is running smoothly Allow the pump to cycle slowly until all air is pushed out of the lines the fluid will be flowing i...

Page 7: ...he air and fluid hoses from the pump Disassemble the fluid pump and accessories See Service to disassemble the pump 4 Wash all the pump parts with an alkaline detergent at the manufacturer s recommend...

Page 8: ...8 307056K Notes...

Page 9: ...sure closed or clogged air valves etc Exhausted fluid supply Obstructed fluid line valves dispensing valve etc Worn throat packing 8 Damaged cylinder o rings 13 Clear air line or increase air supply O...

Page 10: ...ri cant when reassembling 1 Install the u cup packing 8 and throat bearing 17 in the throat packing housing 24 The lips of the u cup must face down into the housing and the lip of the bearing must fac...

Page 11: ...ing Assembly Detail B Piston Valve Assembly 0512 8 24 13 13 3 25 20 19 9 26 10 23 16 20 18 1 6 7 12 21 22 11 7 12 15 5 3 2 14 3 Ref 0630 0629 0628 See Detail A A 17 See Detail B See Detail C Lips must...

Page 12: ...12 307056K Parts 0334A 22 6 7 12 21 4 11 7 12 24 13 3 25 20 19 9 26 2 15 5 13 14 10 18 23 16 20 1 17 8 28...

Page 13: ...eve 1 18 167 970 HOUSING intake valve 1 19 167 971 SEAL piston neoprene 1 20 167 972 O RING nitrile rubber 3 are spares 6 21 167 974 ROD connecting 1 22 167 975 HOUSING retainer 1 23 169 626 PIN strai...

Page 14: ...201 mm 56 8 in 1443 mm 45 in 1143 mm 36 7 in 933 mm 11 in 280 mm 3 4 npt f Air Exhaust Outlet 5 69 in 145 mm dia 2 12 in 54 mm dia 2 22 in 56 4 mm Pin Length Grounding Lug 3 8 npt f Air Inlet 1 1 2 in...

Page 15: ...at 60 cycles per minute 2 3 gallons 8 7 liters Air consumption approximately 8 scfm 0 224 m minute per gallon 3 8 liters at 100 psi 7 bar air pressure Minimum air hose size 0 5 in 13 mm ID Maximum ope...

Reviews: