307056Ką15
Technical Data
Category
Data
Maximum fluid working pressure
600 psi (41 bar)
Maximum air input pressure
120 psi (8 bar)
Ratio
5:1
Pump cycles per gallon (3.8 liters)
28
Fluid flow at 60 cycles per minute
2.3 gallons (8.7 liters)
Air consumption
approximately 8 scfm (0.224 m
#
/minute) per gallon (3.8 liters) at
100 psi (7 bar) air pressure
Minimum air hose size
0.5 in. (13 mm) ID
Maximum operating temperature for
displacement pump
250
_
F (121
_
C)
Maximum operating temperature for air
motor
200
_
F (93
_
C)
Weight
33 lb (15 kg)
Wetted parts
Stainless steel, buna-N, neoprene (USDA approved)