![Graco LineLazer v 3900 Operation Manual Download Page 27](http://html1.mh-extra.com/html/graco/linelazer-v-3900/linelazer-v-3900_operation-manual_2252229027.webp)
LineLazer V LiveLook Display
3A3388A Operation
27
3.
Press to
select
Setup/Information.
4.
Press
for Calibration. Set TRAVEL DIST to 25 ft
(7.6m) or longer. Longer distances ensure better
accuracy, depending on conditions.
\
5.
Align part of the unit with 1 foot (30.5cm) on steel
tape.
6.
Push
to start calibration.
7.
Move striper forward. Keep unit aligned with steel
tape.
8.
Stop when chosen part of unit aligns with 26-ft (8m),
or distance entered, on steel tape (25-ft./ 7.6m dis-
tance).
9.
Push
to complete calibration.
•
Calibration is not complete when the exclamation
symbol
is
displayed.
•
Calibration is finished when the check mark symbol
is displayed.
10. Calibration is now complete.
Go to
Measure Mode (Standard Series)
, page 29, and
verify accuracy by measuring the tape.