Operation
26
332230T
Bead Timing With Gun
1. Use air flow restrictor valves to help time the
opening and closing of the bead guns to best
match the start and stop of paint lines.
2. Valve (X) is exhausting air and will control the timing
end of the bead application. Valve (Y) is sending air
to the gun and will control the timing of the start of
the bead application.
3. Turning the valve clockwise will delay gun
opening/closing time. Turning the valve
counter-clockwise will speed up gun
opening/closing time.
To air tank
Exhaust
To
bead gun
Y
X
ti21326a
NOTICE
Never store glass beads in tank between jobs. Begin the
day with moisture-free beads. Moisture will cause glass
beads to resist flow or solidify over time.
If moisture or condensation is present on tank interior,
leave lid open until dry. When operating without the bead
system, always leave the moisture drain valve open.