Connect Hoses and Mount Pump
1.
Using Loctite Pipe Sealant, screw the hose stud
(10) of the suction hose into the pump’s intake
housing. See F
from the pump base opposite the outlet, and
assemble the hanging bracket (19) to the pump with
the provided screw (9)—use the lockwasher that
was on the replaced screw.
2.
Using Loctite
®
Pipe Sealant, screw the accumulator
(7) inlet adapter into the pump outlet. Connect the
fluid hose to the accumulator, the nozzle to the
spray valve, and the air line lubricator (3) to the
pump air inlet. Hang the pump on your cleaning
solution drum.
NOTE: The filter on the suction hose should be
about 1/2 in. (12.7 mm) off the bottom of the drum. If
the hose is too long, cut it off as necessary.
3.
Close the air ball valve (24), then connect your 1/2
ID (min) air supply hose to the 1/2 nptm(f) inlet
union (15)—do not use thread sealer. Install an
accessory air filter and water separator to remove
excessive moisture that could cause air motor icing.
Pour high quality SAE 10 into the lubricator until oil
reaches the level mark on the sight glass.
NOTICE
Oils containing phosphate ester or chlorinated hydro-
carbons are not compatible with the plastic bowl of
the lubricator—be sure that oil used to lubricate the
compressor is free of these additives.