Appendix B - ADM Setup Screens Overview
70
3A2175Z
To edit the temperature setpoint and alarms for a par
-
ticular component:
1. Press the Enter Screen button and navigate to the
component you wish to edit.
2. Press the enter key to display the setpoint and
alarm values associated with that component.
3. Edit the setpoint and alarm values and then press
the page back button to return to the previous
screen.
Conditioning Screen 3
This screen allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically. Press the Enter Screen button and
adjust the on and off durations as desired.
When the system is in Night Mode and in an “On” cycle,
the system will circulate in low pressure. The installed
conditioning zones will be on and controlling to their
respective setpoints. When the system is in Night Mode
and in an “Off” cycle, the system will be idle. The
system will not be circulating, and the conditioning
zones will not be actively controlling temperature. When
in Night Mode, supply tanks will not fill.
NOTE:
Gray fields on this screen are items unavailable
at this time. Future product releases will incorporate
these features.
NOTE:
All components are shown installed for refer
-
ence only. Only 4 components can be installed at one
time.