Appendix B - ADM Setup Screens Overview
66
3A2175Z
Pre Dispense Delay is a feature where the HFR can
delay the start of a dispense until the user has pressed
and held the foot switch for the duration entered. For
example, if the user enters a five second duration, the
footswitch must be held on continuously for five sec
-
onds before the HFR will start a dispense. This feature
is not available for circulation systems or applicable for
P2/Fusion Dispense Valve applications. This feature
can not be active if the Post Dispense Shot Disable fea
-
ture is active.
System Screen 3
This screen allows the user to edit the labels for the A
(Red) and B (Blue) sides of the machine. The labels set
for the A (Red) and B (Blue) sides of the machine are
displayed throughout the screens. Labels are limited to
five characters.
To edit a label:
1. Press
.
2.
To edit the A (Red) label
, press .
T
o edit the B (Blue) label
, press the down arrow
then press . The keyboard will appear on the
on page
3. Use arrow keys to select the desired letter and
press to accept the letter. To erase all text,
press the Eraser softkey. To go back one letter,
press the Back Arrow softkey.
4. When finished entering the new label, press
the
button twice.
The pressure imbalance setting may be set from this
screen. Pressure imbalance is the allowable difference
in pressure between the two materials before an alarm
is triggered. The input range is 250-2000 psi (2-14 MPa,
17-138 bar).
Pressure
Imbalance
Setting