Installation
3A6714C
9
System Configuration and Wiring
Fuses
Fuse kits are available from Graco. The following table
identifies the correct fuse to use for the input voltage
and the corresponding Graco Kit number.
Recommendations for Pump Usage in
Harsh Environments
•
Use pump with CPC style power cable.
•
Use a corrosion preventative electrical grease on all
contacts.
Wiring and Installation Diagrams
NOTE:
Wire colors provided on these pages refer only
to the Graco power cable.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
NOTICE
Fuses (user supplied) are required on all DC models.
To avoid equipment damage:
•
Never operate pump DC models without a fuse
installed.
•
A fuse of the correct amperage must be installed in
line with the power entry to the system.
Fuse Value
Graco Kit No.
Applicable
Model
10A
26C916
25R802
25R803
25R806
25R809
25R810
25R822
25R823
25R826
25R829
25R730
5A
26C917
25R800
25R807
25R820
25R827
7.5A
571039
25R801
25R804
25R805
25R808
25R821
25R824
25R825
25R828
NOTICE
The stirring paddle should rotate clockwise (as viewed
from the top) (F
. 6) when power is applied. Allowing
the stirring paddle to rotate counterclockwise dam-
ages the pump’s internal components.
If the stirring paddle is rotating counterclockwise, stop
the pump immediately. Check that the wiring is correct
and make any necessary changes.
If the motor does not run after power is supplied,
check the pump wiring.
F
IG
. 6