Setup
18
3A6714C
Priming
It is not necessary to prime the pump every time the
pump is filled. The pump only requires priming the first
time it is used, or if it is allowed to run dry.
1.
Loosen the pump element fitting (F
. 19).
NOTE:
When loosening the pump element fitting, do not
loosen the pump element. Loosening the pump element
changes the output volume and causes leakage.
2.
Only run the pump until air is no longer dispensed
with the lubricant out of element fitting (F
3.
Tighten the pump element fitting using two
wrenches working in opposite directions (F
. 21).
F
IG
. 19
F
IG
. 20
F
IG
. 21