Controller Operation
3A6714C
23
After the ENTER button is
pressed, the second digit
begins to blink. The OFF
LED and HH dot remain
lighted.
This confirms that the sec-
ond digit for OFF TIME is
being configured in Hours
(HH).
3.
Press the UP or DOWN
arrows to select the sec-
ond digit.
4.
Press the ENTER button
to save the selection.
The controller automatically switches to RUN MODE.
ADVANCED PROGRAMMING
The Seven Advanced Programming Menu Descriptions
are:
•
A1 - PIN Entry Enable/Setting Up the PIN Code,
page 23
•
A2 - Prelube and Delay, page 25
•
A3 - Low-Level Alert Duration, page 25
•
A4 - Missed Cycle Threshold, page 25
•
A5 - Low-Level Power Cycle Retry, page 25
•
A6 - Low-Level Alert Enable, page 25
•
A7 - Cycle Count Enable, page 25
To access ADVANCED PROGRAMING:
1.
Press both the UP and
DOWN arrow buttons for
3 seconds to enter
SETUP MODE.
2.
In SETUP MODE, press and hold
the UP arrow for 10 seconds.
The display reads A1. This confirms
that the controller is in the
ADVANCED PROGRAMMING set-
tings.
After entering ADVANCED PROGRAMMING, if no activ-
ity is detected for 60 seconds, a timeout occurs and the
controller resumes RUN MODE.
Press the ENTER button to advance to the
configurable portion of the specific settings.
1.
Press the UP or DOWN
arrows to configure the
selection.
For ON or OFF selection:
-
ON: UP arrow
-
OFF: DOWN arrow
2.
After completing configuration, press the
ENTER button to save and proceed to
the next ADVANCED PROGRAMMING
settings.
After all of the ADVANCED PROGRAMMING settings
are configured, press the ENTER button to return the
controller to RUN MODE.
Advanced Programming Menu Descriptions
A1 – PIN Entry Enable/Setting Up the PIN Code
A PIN Code provides additional controller security by
requiring that a PIN Code be entered before gaining
access to SETUP MODE.
NOTE:
The PIN Code can be configured to be any num-
ber between (and including) 00 and 99.
To set up the PIN Code:
1.
2.
When A1 appears on the display, press
the ENTER button. Either On (PIN Code
ON) or OF (PIN Code OFF) displays.
•
On (ON) - Select On to configure the controller to
require that a PIN Code be entered prior to
accessing SET UP Mode.
-