Controller Operation
22
3A6714C
3.
Press the UP or DOWN
arrows to select the sec-
ond digit.
4.
Press the ENTER button
to save the selection.
The controller automatically switches to OFF TIME con-
figuration.
ON TIME Configuration (Cycles)
NOTE:
The proximity switch accessory must be installed
and Cycle Count enabled in Advanced Programming
(page 23) before the number of cycles can be config-
ured in SETUP MODE.
Notice the following on the controller:
-
The LED next to the
Clock in the ON field illu-
minates
-
The display reads “CY”
to identify that the ON
TIME is configured for
Cycles Counts.
NOTE:
The number of cycles counts can range from 1
to 99.
1.
Press the ENTER button to
advance the display.
The first digit on the display
begins to blink. This confirms
that the controller is ready for
the cycle count to be config-
ured.
2.
Press the UP or DOWN
arrows to select the first
digit.
3.
Press the ENTER button to save the
selection.
After the ENTER button is
pressed, the second digit
begins to blink. The ON LED
remains lighted.
This confirms that the second
digit for ON TIME is being con-
figured in Minutes (MM).
4.
Press the UP or DOWN
arrows to select the sec-
ond digit.
5.
Press the ENTER button to save the
selection.
The controller automatically switches to OFF TIME con-
figuration.
OFF TIME Configuration (Min./Hrs)
Notice the following on the controller:
-
The LED next to the
Clock in the OFF
field is lighted.
-
The first digit on the
display begins to
blink.
-
A dot on the display
under the HH illumi-
nates.
This confirms that the controller is ready for the first digit
to be configured for OFF TIME in Hours (HH).
NOTE
: The OFF TIME must be configured between 15
min, and 99 hours.
1.
Press the UP or Down
arrows to select the first
digit.
2.
Press the ENTER button
to save the selection.