4D350 Models
Fluid Pressure
Approximate Cycles per Minute
PSI
(MPa, bar)
0
0
1
(3.8)
1.5
(5.7)
2.5
(9.5)
3.5
(13.3)
0.5
(1.9)
2
(7.6)
3
(11.4)
4
(15.1)
0
12
23
20
34
43
50
(0.3, 3)
100
(0.7, 7)
150
(1.0, 10)
200
(1.4, 14)
250
(1.7, 17)
300
(2.1, 21)
350
(2.4, 24)
400
(2.8, 28)
450
(3.1, 31)
A
B
C
Fluid Flow — gpm (lpm)
Operating Air Pressure
A
100 psi (0.7 MPa, 7.0 bar)
B
70 psi (0.48 MPa, 4.8 bar)
C
40 psi (0.28 MPa, 2.8 bar)
Air Consumption
Approximate Cycles per Minute
How to Read the Charts
1. Locate fluid flow rate along
bottom of chart.
2. Follow vertical line up to
intersection with selected
operating air pressure
curve.
3. Follow left to scale to read
fluid outlet pressure (top
chart) or air consumption
(bottom chart)
scfm
(Nm
3
/min.)
0
0
1
(3.8)
1.5
(5.7)
2.5
(9.5)
3.5
(13.3)
0.5
(1.9)
2
(7.6)
3
(11.4)
4
(15.1)
0
12
23
20
34
43
10
(0.28)
20
(0.57)
25
(0.71)
30
(0.85)
A
B
C
5
(0.14)
15
(0.42)
Fluid Flow — gpm (lpm)
333015E
37
Summary of Contents for Endura-Flo 4D150