Install the Fluid Manifolds
1. Install new o-rings (38) on the two inlet and two
outlet ports.
2. Align the arrow on the check cartridge (9) with the
arrow on the port. Install a new check cartridge
in each inlet and outlet port.
3. The manifolds are identical, but it is likely that
the inlet and outlet manifold will have different
fittings. Install the inlet manifold (2) on the
ports that have the arrow facing in toward
the pump. Install the outlet manifold (2) on
the ports that have the arrow facing out away
from the pump. Start all screws (16), then see
.
1
Inlet manifold.
2
Outlet manifold.
28
333015E
Summary of Contents for Endura-Flo 4D150
Page 9: ...Installation Notes 333015E 9...