Operation
8
332540B
Filling Reservoir
1.
Connect lubricant supply hose from remote filling
station pump to Fill Port (G).
2.
Remove plug from Overflow Port (H).
3.
Slowly turn on supply lubricant until level of lubricant
reaches Overflow Port (H).
NOTE:
For systems with a follower plate, fill unit until the
follower plate reaches the Overflow Port (H).
4.
Disconnect lubricants supply hose from Fill Port (G).
5.
Plug Fill Port (G) and Overflow Port (H).
Shutdown
For normal system shut down, disconnect power by
turning off the ignition switch (C).
NOTICE
To prevent damage to the unit:
• Check Breather vent (J) for proper operation
before filling reservoir.
• Open Overflow Port (H) before filling for visual
inspection of lubricant level.
• Do not fill beyond Overflow Port (H).
• Do not use Overflow Port (H) to fill reservoir.
NOTICE
Never allow pump to run dry of the fluid being pumped.
Running a pump dry can damage the pump.