
Appendix B - Data Exchanged
28
3A6338B
Integration System Status
Integration System Status is a boolean that shows the
status of the Integration System I/O pin. The following
values correspond to the different states of the
Integration System Status boolean.
Integration Analog Flow Rate Enabled
Integration Analog Flow Rate Enabled is a boolean that
can enable usage of the Integration Analog Flow Rate
I/O pin. The following values correspond to the different
states of the Integration Analog Flow Rate Enabled
boolean.
Integration Analog Flow Rate Status
Integration Analog Flow Rate Status is an integer used
to define the voltage on the Analog Flow Rate I/O pin.
NOTE:
This integer can only be read by the PLC.
Integration Sequence Selected Enabled
Integration Sequence Selected Enabled is a boolean
that can enable usage of the Integration Sequence
Selected I/O pins on the ADM. The following values
correspond to the different states of the Sequence
Selected Enabled boolean.
Integration Sequence Selected Status
Integration Sequence Selected Status is an integer
used to define the active sequence on the EFR by using
I/O pins on the ADM as bits. When read, the integer
results in the Active Sequence in the EFR system.
Example
: If the integer has a value of 2, the Active
Sequence is 2.
NOTE:
This integer can only be read by the PLC.
Red Pump Cycles
Red Pump Cycles is an integer used to define the
number of times the red pump has cycled. This can be
reset by sending a value zero from the PLC over the
Data Exchange.
Red Pump Lifetime Cycles
Red Pump Lifetime Cycles is an integer used to define
the number of times the pump has cycled during its
lifetime.
NOTE:
This integer can only be read by the PLC.
Blue Pump Cycles
Blue Pump Cycles is an integer used to define the
number of times the blue pump has cycled. This can be
reset by sending a value zero from the PLC over the
Data Exchange.
Blue Pump Lifetime Cycles
Blue Pump Lifetime Cycles is an integer used to define
the number of times the pump has cycled during its
lifetime.
NOTE:
This integer can only be read by the PLC.
Dispense Valve Cycles
Dispense Valve Cycles is an integer used to define the
number of times the dispense valve has opened. This
can be reset by sending a value zero from the PLC over
the Data Exchange.
Dispense Valve Lifetime Cycles
Dispense Valve Lifetime Cycles is an integer used to
define the number of times the dispense valve has
opened during its lifetime.
NOTE:
This integer can only be read by the PLC.
Value
Integration System
Status State
0
Not Active
1
Active
Value
Integration Analog Flow
Rate Enabled State
0
Not Enabled
1
Enabled
Value
Integration Sequence
Selected Enabled State
0
Not Enabled
1
Enabled