![Graco CGM 25B127 Instructions - Parts Manual Download Page 11](http://html1.mh-extra.com/html/graco/cgm-25b127/cgm-25b127_instructions-parts-manual_2251101011.webp)
Available Internal Data
3A6338B
11
Automation Outputs (signals from PLC to EFR system)
Instance ID
Description
Data Type
BIT
Output Byte
Index’s
1
System Enable Request
Boolean
0
0
2
System Shutdown Request
Boolean
1
3
Start Current Sequence/Step, Trigger Operator Mode
Boolean
2
4
Pause Current Sequence
Boolean
3
5
Stop Current Sequence
Boolean
4
6
Priming Request
Boolean
5
7
Purge Request
Boolean
6
8
Parking Request
Boolean
7
9
Depressurizing Request
Boolean
8
1
10
{Reserved Bits}
Boolean
9-15
11
{Reserved Bits}
uint8
0-7
2
12
Desired Active Sequence
uint8
0-7
3
13
Acknowledging of the Active Error Number
uint8
0-7
4
14
Desired Operator Mode Dispense Flow Rate (XXXX
cc/min)
uint16
0-7
5
8-15
6
15
Data Exchanged Element Desired
uint8
0-7
7
16
Data Exchanged Element Desired Value
uint16
0-7
8
8-15
9
17
Desired Step of the Active Sequence
uint8
0-7
10
19
Desired Step Amount (XXXX.XX)
uint32
0-7
11
8-15
12
16-23
13
24-31
14
19
Desired Step Shot Type
uint8
0-7
15
20
Desired Step Flow Rate (XXXX cc/min)
uint16
0-7
16
8-15
17
21
Desired Step Calibration (XX.XX)
uint16
0-7
18
8-15
19
22
{Reserved Word}
uint16
0-7
20
8-15
21