Appendix B - Data Exchanged
26
3A6338B
Below is a list of explanations of each individual Data
Exchange Element.
Dispense Mode
Dispense Mode tells the EFR system whether the
system is in weight or volume mode. The following
values correspond to the various dispense modes
offered by the EFR.
ADM Rate Units
ADM Rate Units tells the EFR system what units the
rate will be displayed in on the ADM. The following
values correspond to the various rate units the EFR
ADM offers.
ADM Pressure Units
ADM Pressure Units tells the EFR system what units the
pressure will be displayed in on the ADM. The following
values correspond to the various pressure units the EFR
ADM offers.
Pressure Imbalance Alarm Enabled
Pressure Imbalance Alarm Enabled is a boolean that
can enable or disable the ability to view pressure
imbalances between the red pump and the blue pump.
The following values correspond to the different states
the Pressure Imbalance Alarm boolean can be set to.
Pressure Imbalance Alarm Level
Pressure Imbalance Alarm Level is an integer used to
trigger the pressure imbalance alarm.
Red Pump Size
Red Pump Size is an integer used to define the size of
the red z pump.
Blue Pump Size
Blue Pump Size is an integer used to define the size of
the blue z pump.
Red Specific Gravity
Red Specific Gravity is an integer used to define the
specific gravity of the material in the red z pump.
Blue Specific Gravity
Blue Specific Gravity is an integer used to define the
specific gravity of the material in the blue z pump.
Gel Timer Enabled
Gel Timer Enabled is a boolean that can enable or
disable the Gel Timer feature. The following values
correspond to the different states the Gel Timer boolean
can be set to.
Gel Timer Idle Period
Gel Timer Idle Period is an integer used to define the
idle state of the gel timer before the gel timer causes a
dispense.
Gel Timer Alarm
Gel Timer Alarm is an integer used to define the alarm
state of the gel timer.
Gel Timer Repeat Unit
Gel Timer Repeat Unit is an integer used to define the
amount of material dispensed for the gel timer shot.
Value
Dispense Mode State
0
Weight Mode
1
Volume Mode
Value
Rate Units State
0
Per Minute
1
Per Second
2
Per Hour
Value
Pressure Units State
0
PSI
1
Bar
Value
Pressure Imbalance
Alarm State
0
Not Enabled
1
Enabled
Value
Gel Timer Enabled State
0
Not Enabled
1
Enabled