The Graco Warranty and Disclaimers

Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.  With the exception of
any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or
replace any part of the equipment determined by Graco to be defective.  This warranty applies only when the equipment is installed,
operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or
substitution of non-Graco component parts.  Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance or structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect.  If the claimed defect is verified, Graco will repair or replace free of charge any defective parts.  The
equipment will be returned to the original purchaser transportation prepaid.  If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.  The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available.  Any action for breach of warranty must be brought within two (2) years of the
date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT
NOT MANUFACTURED BY GRACO.

  These items sold, but not manufactured by Graco (such as electric motors, gas engines,

switches, hose, etc.), are subject to the warranty, if any, of their manufacturer.  Graco will provide purchaser with reasonable assistance
in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties
reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures
judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Phone Number

TO PLACE AN ORDER

, contact your Graco distributor, or call this number to identify the distributor closest to you:

1–800–367–4023 Toll Free

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices:

 Minneapolis, Detroit

International Offices:

 Belgium, Korea, Hong Kong, Japan

GRACO INC.

P.O. BOX 1441

MINNEAPOLIS, MN

55440–1441

PRINTED IN U.S.A. 307132 June 1974, Revised August 2000

Summary of Contents for BULLDOG HYDRA-CAT 208958

Page 1: ...l 209000 Series E 2 1 Mix Ratio Model 209001 Series E 3 1 Mix Ratio Model 209002 Series E 4 1 Mix Ratio Model 209003 Series E 2 1 2 1 Mix Ratio RELIEF VALVE INSTALLATION KITS Required for safe operati...

Page 2: ...tatic sparking or you feel an electric shock while using this equipment stop spray ing immediately Do not use the equipment until you identify and correct the problem Provide fresh air ventilation to...

Page 3: ...the equipment Check the hoses tubes and couplings daily Replace worn damaged or loose parts immediately Permanently coupled hoses cannot be repaired replace the entire hose Use only Graco approved ho...

Page 4: ...uid pressures to be achieved A 475 to 575 psi working pressure range relief valve is provided on the secondary side to limit the fluid pressure Do not tamper with this pressure relief valve or serious...

Page 5: ...25 For pressure feed to proportioning pump mount fluid pressure gauges at proportioning pump inlets to properly adjust feed pump pressures 1 1 D A C N E A B A D A M F P F J G G C B H PART A PART B LIG...

Page 6: ...pressures 1 KEY A Bleed type master air valve B Pump runaway valve C Air line lubricator D Air regulator E Air line filter F Fluid filter G Fluid drain valve H Feed pump J Proportioning pump K Solvent...

Page 7: ...m pressed air supply Install a fluid drain valve G at each fluid outlet to re lieve pressure in the system Be sure the valve is pointed downward WARNING INJECTION HAZARD Two accessories the bleed type...

Page 8: ...pt m fluid outlets of relief valves Fig 1 05227 3 8 npt m Part A Fluid Outlet 3 4 npt m Part A Fluid Inlet 3 8 npt m Part B Fluid Outlet 3 4 npt m Part B Fluid Inlet Part A Part B D A G C B G 209005 R...

Page 9: ...nding Wire and Clamp P N 237569 25 feet 7 6 m long 12 ga 2 Air and fluid hoses Use only electrically conduc tive hoses with a maximum of 500 feet 150 m combined hose length to ensure grounding conti n...

Page 10: ...gh pressure can be injected through the skin and cause serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the Pressure Relief Procedure whenever you a...

Page 11: ...o use When clean solvent is coming out of the gun dispensing valve re move the solvent supply from the feed pumps intakes Slowly run the pump to push all the solvent out of the lines then stop the pum...

Page 12: ...n the eyes or on the skin and property dam age never exceed the maximum air and fluid work ing pressure of the lowest rated component in your system See page 10 Reconnect the fluid dispensing hose to...

Page 13: ...king nut should be tight enough to prevent leakage no tighter Too tight an adjustment will cause the packings to bind or wear prematurely and leak Relieve the pres sure before adjusting the packing nu...

Page 14: ...or for assistance in selecting the proper type of flow restrictor for your application 1 Disconnect the fluid hoses from the mixer inlet valves taking note of which hose was connected to which valve T...

Page 15: ...s 9 from the intakes of the displacement pumps and remove the manifold 20 3 Remove the two retaining nuts 6 from the two outer pumps displacement rods E Screw the fluid pump retaining rings 15 off the...

Page 16: ...5 222012 24 1 0 064 0 24 2400 16 8 168 100 0 7 7 3 1 222012 222017 222012 25 1 0 061 0 23 2500 17 170 100 0 7 7 4 1 222012 222019 222012 27 1 0 057 0 22 2500 17 170 93 0 6 6 4 Exceeds the pressure rat...

Page 17: ...307132 17 Notes...

Page 18: ...n manual 307049 Displacement pump seized Service lower pump see instruction manual 307944 System speeds up or runs erratically Fluid containers are empty Check often keep filled Air in fluid lines Pur...

Page 19: ...nder on upstroke diving on top of change over Increase pressure on feed pump Check inlet filter screen Check foot valve Pump operates but part B output pres sure drops during both strokes Dirty worn o...

Page 20: ...t pumps and remove the manifold 20 3 Remove the two locknuts 6 from the two outer pumps displacement rods E Screw the fluid pump retaining rings 15 off the fluid pumps use a screwdriver and hammer to...

Page 21: ...ining rings 15 and washers 14 Thread the displacement rods into the yoke 13 by turning the complete cylinder Install the locknuts 6 loosely on the displacement rods Push the cylinders up into place in...

Page 22: ...4 in 101 6 mm 3 16 in 5 mm dia bolt circles 3 holes 6 9 in 175 3 mm 6 9 in 175 3 mm Throat Seal Liquid Non evaporating solvent for wet cup 206994 8 oz 0 2 liter 206995 1 qt 0 9 liter 206996 1 gal 3 8...

Page 23: ...307132 23 Notes...

Page 24: ...t f fluid outlets 3 4 npt fluid inlets 3 4 npt f air inlet 45 in 1143 mm 23 in 584 mm Mounting Hole Layout 05235 9 in 229 mm diameter 0 44 in 11 2 mm diameter 4 holes 10 5 in 267 mm diameter bolt circ...

Page 25: ...d parts Stainless Steel Tungsten Carbide Chrome Plating Carbon Steel Ultra High Molecular Weight Polyethylene NEVER exceed 2500 psi 17 MPa 170 bar fluid pressure Air Consumable Example When the air pr...

Page 26: ...including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action f...

Reviews: