ToubleShooting Chart
8
309454C
ToubleShooting Chart
Service
Battery Replacement
The Accu-Shot is supplied with two standard alkaline
batteries Size AA 1.5 Volt. The batteries must be
replaced when the LCD display starts to fade or disap-
pears.
1.
Press the RESET button to update the cumulative
total.
2.
Unscrew the battery cap (34). See Fig. 5.
3.
Remove the old batteries (28).
4.
Insert the new batteries (28) with polarity as shown.
5.
Replace the battery cap (34). Ensure that the gas-
ket (32) and tapered spring (31) are correctly posi-
tioned.
Problem
Cause
Solution
LCD fades or disappears
.
Batteries are low.
Replace. See Battery Replacement Pro-
cedure.
Display does not activate.
Batteries are defective or dead.
Replace. See Battery Replacement Pro-
cedure.
Slow or no grease.
Pump pressure is low.
Increase pump pressure.
Shut-off valve is not fully open.
Fully open shut-off valve
Foreign material is jammed in the meter
housing.
Clean the metering chamber. See proce-
dure on page 9.
WARNING
Pressurized Equipment Hazard
To reduce the risk of serious injury, including
splashing in the eyes or on the skin or injury
from moving parts, follow the “Before Dis-
pensing Grease” on page 7 before checking or servic-
ing the equipment and whenever you are instructed to
relieve the pressure.
CAUTION
The display will remain off after the batteries have
been replaced. This is because the Accu-Shot is
equipped with a system that prevents powering the
electrical components during battery replacement. To
turn the LCD display on press the RESET button.
The Accu-Shot will display the same cumulative total
as before battery replacement and the partial delivery
meter will display zero.
TI1702A
Fig. 5
28
31
32
34