Overview
4
309454C
Overview
The Accu-Shot grease nozzle flow rate depends on the specific operating conditions and can vary considerably
according to the resistance of new grease which will vary depending on pipe size and length, working temperature,
obstructions, and pump efficiency, etc.
With its compact dimensions and limited weight, the Accu-Shot can replace ordinary grease nozzles.The amount of
grease delivered by the Accu-Shot nozzle is accurately measured and shown directly on the LCD. Correct greasing is
guaranteed by the re-settable partial delivery meter. Grease consumption is recorded by calculation and display of
the total amount delivered.
Installation
Typical Installation
The installation shown in Fig.1 is only a guide.The com-
ponents shown are typical; however, it is not a complete
system design. Contact your Graco distributor for assis-
tance in designing a system to suit your particular needs
Pressure Relief Procedure
KEY
DESCRIPTION
A
Fluid Shut-off valve
B
Hose
C
Hose reel fluid inlet hose
D
Hose reel
E
Accu-Shot electronic grease meter
F
2 in. swivel
Caution
This dispense valve is not designed for in-line
installation. Do not install with a shut-off valve on
the outlet side of the meter. Such installation
could result in damage to the meter housing
cover.
WARNING
Pressurized Equipment Hazard
The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious injury
from pressurized fluid, accidental spray from the dis-
pense valve, or splashing fluid, follow the Pressure
Relief Procedure when you:
•
Are instructed to relieve pressure
•
Check, clean, or service any system equipment
•
Install or clean fluid nozzles or filter.
A
C
D
B
E
Fig. 1
F
Summary of Contents for Accu-Shot 233807
Page 15: ...Notes 309454C 15 Notes ...