background image

Alarm LED

MC

+5V

VR1

VCC :Connect + (DC24V±10%)

G  :Connect -(GND)

AOUT:

Analog output

    (0~10V/4~20mA)

ALM:

Alarm output 

   ( A or B contact、ON/OFF)

CM  :Alarm return

SET

Photo MOS FET

Specifications

*3 Analog output…After input the power, green LED will be on. Do not adjust(touch) the volume after shipping.

*2

 

Default setting of alarm output is  5L=2.5L/min、10L=5L/min、30L=15.0L/min. 

This is the basic specification for JPSL. Please read them carefully for safe use.

Max. DC 100mA

Max. DC 40V

0~50℃ (No freezing ,no dewing)

Certification, regulation

Wetted material

Adapter size

Weight

RoHS

Body PPS, FKM    Adapter SUS304

Rc3/8" Quick fitting

Display

Alarm: 2colors LED

Voltage output

Current output

Models

Rated flow range

Fluid

Detecting method

Fluid temperature

Ambient temperature

Accuracy

Maximum working pressure

Withstanding pressure

Responsivity

Power supply

Current consumption

Industrial water, water

Karman vortex

0~90℃ (No freezing ,no dewing)

Flow rate output: ±2% full scale 

1.0MPa

1.5MPa (at 20℃)

Analog output

0~10V

4~20mA

A or B output (select one)

Configuration and Dimensions

*2

*3

*1

*Default setting  is one of outputs at the time of shipment.

*White wire is spare wire when alarm output, yellow and blue are spare wires when  analog output.

VCC

G

AOUT

ALM

CM

Red

Black

White

Yellow

Blue

C

Connect -

Analog
output 

Alarm

output

Alarm

return

No need of earth

(COM)

DC24V±10%

0~10V

4~20mA

Photo MOS FFT( A )

Choose one of
 two outputs.

Choose one of
 two outputs.

Cside of power supply.
24V to 

J

PSL.

Connect -side of power supply.
It is GND(0V) of 

J

PSL.

It is -line of analog output.

Flow rate is changed to the
electric signal and transmitted
 to the device.
 +line is for analog output.

Alarm output return circuit.
Independent from GND

Alarming signal to equipment.
(A) flow rate ≧ alarm value : ON
(B) flow rate < alarm value : ON

Photo MOS FFT( B )

J

PSL   Equipment

J

PSL   Equipment

J

PSL   Equipment

J

PSL   Equipment

J

PSL   Equipment

【cable functions】

Contact between the spare wires or between wires and external equipment
could cause accident or damage. Please insulate each wire when used.

*1 Voltage more than specified on the table will damage the product.

Alarm output

The electric circuit, substrate, is attached on a wetted part of the  body which
is covered with a cover. You find an alarm setting button and volume inside of the
cover,  and a cables for interface on the side.

*Green LED will be on with analog output by power input. 

FLO

W

VOLU

ME

paldra

S ET

FLOW

VOLUME

paldra

S ET

101

38

HEX22

50

24

51

33

Rc 3/8

JPSL-5L

JPSL-10L

JPSL-30L

0.5~5.0L /min

1.5~10.0L /min

5.0~30.0L /min

155g

85kPa

60kPa

46kPa

Sampling 1s

DC24V±10%

Max. 30mA (Current output Max. 50mA) 

PALDRA Instructions

manual

Warning

caution

Never do it.

Do it only with following instructions.

● Please read carefully the instructions before you use our product.

Before using our product.

Safety information

Warning

Unusual or faulty conditions

Working environments

Working environments

In the humid or dewing environment, it could cause accident or damage because of moisture. 

● Please follow the procedures, conditions and cautions as per the instructions.

Do not use outside. This product is only for inside.

Cables

Caution

Packaging and carrying.

Installations

Maintenance

Others

JPSL-5L/10L/30L

Karman vortex flow meter

Features

Karman vortex flow meter
J

PSL-5L/10L/30L is the new

series of flow meters to measure
flow rate, with simple functions
and reasonable price.
 Due to compact construction it
can be installed in narrow space
and simple structure resulting
easy maintenance, easy
installation and de-installation.

Mishandling could cause injury
or even death at drastic
conditions.

Mishandling could cause disability,
fire or other damages to the building
or properties.

If you continue using our product under the unusual or faulty connections or
conditions like as smoking, foul smell, unstable and malfunction, it could cause
fire or accident. Cut the power supply immediately and contact to us. Do not try
to repair the product yourself. 

Our products are NOT explosion-proof. Do not use in the dangerous environment with
flammable, explosive, or corrosive gas.

In the vibration, impulsion or pulsation environment, it could cause malfunction,
some accident or damage.

Installation in high temperature environment as near to heat instruments could
cause some accident or damage as the heat instrument will led the temp rise inside
the flow meter. Please use our product as instructed in the manual.

Please do not put heavy objects on the cables or pull the cables from flow
meter body, it could cause accident or damage. 

Please follow the Instructions for  "wiring", "Output signal "other wise,
it could cause accident or damages. 

Magnetic power, electromagnetic wave, radioactive ray or ultraviolet rays
could cause accident or damage.

Electric corrosion or static electricity could cause accident or damages.

In electrically noisy environments as like around high-frequency power
source could cause accident or damages.

Install the filter upper flow/Inlet to clear some piece of metal or small
objects if needed.

Remove the bubbles in the fluid for accurate measurement of flow rate.

Do not drop ,Handle with care otherwise The flow meter could damage or
cause malfunctioning.

Mind your fingers while plumbing a sensor or you could get injured.

Contact us for overhauling, adjusting or repairing. Please make sure not
to touch an electronic substrate inside of flow meter.

Only a person who has technical knowledge and experiences could do
plumbing, wiring, maintenance or overhauling.

while installation or maintenance please shut off the power and water
supply for your safety.

Please contact us if you received damaged or deformed product.

Cable

HEX22

flow direction

Plumbing adapter

LED switch display

Cover

Body

A W M 2 0 2 7 6   3 c o r e s ,
0 . 2 m m 2 ,   l e n g t h   2 0 0 m m ,
u n p r o c e s s e d   t e r m i n a l

Switch set panel

( U n i t : m m )

Maximum load current

Maximum applied voltage

Output mode

Pressure loss 

(at the maximum flow rate)

(while orderingselect
 only one output)

Wiring (interface)

【Block diagram】

Vortex
shedder

Vibrate

element

Processor

Detecting

 part

Power circuit

Sign

Color

Name

Direction

Characteristic

Output selection

Operation and usage

6

5

www.jetec.com.tw

久德電子      

TEL:

+886-4-23729418

FAX:

+886-4-23724011 (40349)

台中市西區福人街11號