background image

Instructions

Grease Jockey
Lubrication Controller

334662B

For controlling and monitoring an automated lubrication system. 

Not approved for outdoor use or use in explosive atmospheres or hazardous locations.

Model: 24W482

Important Safety Instructions
Read all warnings and instructions in this 
manual. Save these instructions.

EN

Summary of Contents for 24W482

Page 1: ...controlling and monitoring an automated lubrication system Not approved for outdoor use or use in explosive atmospheres or hazardous locations Model 24W482 Important Safety Instructions Read all warni...

Page 2: ...are compatible with equipment wetted parts See Technical Data in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request MSDS from di...

Page 3: ...the right or to the next setup step In RUN MODE activates the pump for one com plete ON cycle if actuated during the OFF por tion of the RUN cycle UP and DOWN Direction Arrows E Press and hold both th...

Page 4: ...in FIG 2 is only a guide for selecting and installing system components Contact your Graco distributor for assistance in planning a system to suit your needs FIG 2 Pump Solenoid Timer Fuse user suppli...

Page 5: ...r 1 Select a flat surface to install the Lubrication Con troller Drill mounting holes Refer to Mounting Hole Layout Provided in the Technical Data section of this manual page 13 2 Align junction box w...

Page 6: ...hange this to ON 4 Press the ENTER button to enter the PIN Code 5 Use the UP and DOWN ARROW buttons to move up and down through the num bers 0 9 until the first number in the PIN code is displayed in...

Page 7: ...Time Control a spe cific duration of time elapses Time Control on ti ON Setup 1 on ti is on the display 2 Press ENTER 3 To set the ON time use the UP or DOWN ARROW to scroll through the numerals 0 5 u...

Page 8: ...next HH number field to the right flashes indicating it is ready for programming 3 Use the UP or DOWN ARROW to scroll through the numerals 0 9 until the desired number appears in the second HH field...

Page 9: ...es sec onds Timer Mode Pump OFF The display indicates the amount of time remaining in the pump OFF cycle counting down the Pump OFF time value see Programming OFF Time Duration page 8 The Time OFF LED...

Page 10: ...being delivered to the pump during pump ON Refer to installation instructions page 4 Ver ify that your machine has been wired correctly Controller output is incorrect Confirm output voltage PUMP from...

Page 11: ...scription Qty 1 BOX enclosure 1 2 LABEL control overlay 1 3 LABEL serial name 1 4 LABEL connector 1 1 3 4 2 Kit No Description 127900 HARNESS Grease Jockey Delphi 280 127899 HARNESS Grease Jockey Delp...

Page 12: ...Pump Control Voltage Power Source Max Switching Voltage 32 VDC Max Switching Current 9A DC Min Switching Current 100 mA DC Protection grade IP54 for indoors and vehicle cab use Enclosure Material ABS...

Page 13: ...Dimensions 334662B 13 Dimensions Mounting Hole Layout 2 75 in 70 0 mm 5 53 in 140 0 mm 1 38 in 35 0 mm 1 57 in 40 0 mm 4 92 in 125 0 mm 2 x 0 2 in 5 0 mm...

Page 14: ...ial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES E...