background image

Warnings 

2

3A1215D

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and 
warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

WARNING

WARNING

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system 

component. See 

Technical Data

 in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical Data

 in all 

equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about 
your material, request MSDS from distributor or retailer.

• Do not leave the work area while equipment is energized or under pressure. Turn off all equipment 

and follow the 

Pressure Relief Procedure 

when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 

manufacturer’s replacement parts only.

• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

Summary of Contents for 24F472

Page 1: ...Cable Remote Switch and Bracket Important Safety Instructions Read all warnings and instructions in this manual Save these instructions POWER ON OFF RESET HOLD BEADS ON BEAD TEST A B C D E F SYSTEM D...

Page 2: ...ee Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read fluid and solvent manufacturer s war...

Page 3: ...released K switch Used in conjunction with the arrow switches to adjust the paint line position to match a previously painted line allows the dash line to be moved forward allows the dash line to be...

Page 4: ...djustable to 1 50 meter NOTE The controller must be calibrated in the units that you desire to use Paint and cycle length are adjustable from 0 0 to 999 9 feet or 0 0 to 99 99 meter Footage counters r...

Page 5: ...line to that button Application Totals The Counter Menu measures the actual paint distance in feet meters from each paint gun This menu also mea sures the gallons liters of paint sprayed by guns 1 2 a...

Page 6: ...allons or liters 1 Press to toggle between units for display mea surements 2 Use adjacent arrows to change pump cycles per unit volume RPS 2900 preset value is 14 9 RoadLazer Tow Behind is 37 Value ma...

Page 7: ...s Pump Calibration D B C D E F A C D E Press to choose between SPACE or CYCLE to be displayed on the main menu Press to choose between GALLONS or LITERS CHANGE Solenoid 4 ENABLE DISABLED Solenoid 6 EN...

Page 8: ...S ON BEAD TEST ADV RET RESET HOLD Diagnostics B Exit Distance 0 Pump 1 0 Pump 2 0 A Reset counters SOLENOIDS 1 2 3 4 5 6 SWITCH TEST CAUTION SOLENOIDS WILL STILL ACTUATE 1 2 3 BEADS ON BEAD TEST ADV R...

Page 9: ...n 6 Driver the RoadLazer in a straight line to the mark at the end of the measured course Stop with the gun arm wheel exactly on the second mark 7 Press button 8 The system is now calibrated System De...

Page 10: ...ed A 4 Toggle the REST HOLD button to center and drive the course This enables the selected guns to begin painting when Point A is reached 5 When the mechanical pointer reaches the end of the desired...

Page 11: ...d using the First Menu 3 Align the mechanical pointer with point A 4 Set gun 1 to Skip and toggle the HOLD RELEASE switch to center 5 When the mechanical point reaches point B set gun 2 to solid 6 Whe...

Page 12: ...sensor alignment Sensor should be 03 in from the tim ing gear and centered Glass beads miss a portion of a stripe when turned on Paint and bead gun delays not set properly Adjust Paint and Bead Gun D...

Page 13: ...Output 1 amp Max 9 Bead Gun 1 Solenoid 2 Output 1 amp Max 10 Bead Gun 2 Solenoid 4 Output 1 amp Max 11 Bead Gun 3 Solenoid 6 Output 1 amp Max 12 Engine Shutdown ground 13 Ground 14 Ground 15 Ground 16...

Page 14: ...ncludes 2 1 2 KNOB mounting 2 3 24F469 CABLE control 1 4 113617 SWITCH remote 1 5 17V199 BRACKET mounting 1 6 24G720 KIT board display RoadLazer 1 7 24G717 KIT board switch toggle 1 8 24G719 KIT board...

Page 15: ...Notes 3A1215D 15 Notes...

Page 16: ...the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY I...