Calibration
3A1657A
11
For MD2 Valve Only --
a.
Use an adjustable wrench to remove the static
mixer.
b.
Install the ratio check adapter onto the dispense
valve.
For L-Head, S-Head, and GX-16 Dispense Valves
Only --
•
If calibrating the A (Red) side,
close the B (Blue)
valve on the fluid manifold. Make sure the A
(Red) valve is open.
•
If calibrating the B (Blue) side,
close the A (Red)
valve on the fluid manifold. Make sure the B
(Blue) valve is open.
NOTE:
The valves on the fluid manifold are closed when
pointing to the side, as shown in F
. 13. They are open
when pointing forwards.
All Assemblies --
9.
Turn the main power switch on the HFR to the ON
position.
10. Press the ADM Power On/Off button (CA) to enable
the system.
11. Press
to dispense a shot to prime the material
lines.
12. Remove container from below the dispense valve.
13. Press
repeatedly to select Standby mode.
14. Press
to access the Setup screens.
15. Use the arrow keys to navigate to System
screen #3.
16. Press
then use the arrow keys to navigate to
the A (Red) and B (Blue) flow meter dropdown
menus.
17. Use the dropdown menus to select the type of flow
meters installed.
F
IG
. 13: Fluid Manifold Valves - shown closed
A
ti17021a
B
F
IG
. 14: Fluid Manifold Valves
ti17021a
CA