Calibration
3A1657A
13
28. Use the arrow keys to navigate to the applicable
A (Red) or B (Blue) weight box below the
icon and enter the weight of the dispensed mate-
rial(s).
29. Record the K-factor(s) shown on the screen after
the material weight(s) are entered.
30. Repeat steps 25 to 29 at least four times to dis-
pense many calibration shots. Record the weights
and K-factors shown on the screen for each shot.
NOTE:
The K-factor should be within 0.5% of the aver-
age value for all runs.
31. If any K-factors are not within 0.5% of the average
K-factor value for all shots then:
a.
Check all electrical connections.
b.
Check material connections.
c.
Check to make sure there is no air in the mate-
rial lines.
32. Perform HFR
Pressure Relief Procedure
. See
HFR operation manual for detailed instructions.
33. Perform dispense valve
Pressure Relief Proce-
dure
. See dispense valve manual, page 2, for
detailed instructions.
34. Verify all air, hydraulic, and material pressures have
been relieved before continuing.
35. Perform HFR
Shutdown
procedure. See HFR oper-
ation manual for detailed instructions.
36. Prepare dispense valve:
For L-Head, S-Head, and GX-16 Dispense Valves
Only --
a.
Remove blocked orifice and replace with origi-
nal orifice.
b.
Clean the used blocked orifice for future use.
c.
Go to step 25 to repeat procedure to calibrate
the other material line.
For Fusion and EP Guns Only --
a.
Remove the ratio check assembly and clean for
future use.
b.
Attach fluid manifold to gun.
For Probler P2 Gun Only --
a.
Remove material lines from calibration kit.
b.
Remove calibration kit and clean for future use.
c.
Attach material lines to gun.
For MD2 Valve Only --
a.
Remove ratio check nozzle and clean for future
use.
b.
Install static mixer.
All Assemblies --
37. Navigate to the System 3 screen then update the
Alarm % value to the desired percent.