308981 35
Husky 515 and 716 Performance Charts
Air Consumption
Test Conditions
: Pump tested in water with inlet submerged.
To find Pump Air Consumption
(scfm or m#/min) at a specific fluid
flow (gpm/lpm) and air pressure (psi/MPa/bar):
1.
Locate fluid flow rate along bottom of chart.
2.
Read vertical line up to intersection with selected air consump-
tion curve.
3.
Follow left to scale to read air consumption.
0
5
10
15
20
25
30
0
2
4
6
8
10
12
14
16
(7.6)
(15.2)
(22.7)
(30.3)
(37.9)
(45.4)
(53.0)
(60.6)
A
B
C
(0.28)
(0.14)
(0.42)
(0.56)
(0.70)
(0.84)
AIR C
O
NSUMPTION- -s
cf
m (c
ub
ic
m
e
ters
/mi
n
)
Air Consumption Curves
A
at 100 psi (0.7 MPa, 7 bar) air pressure
B
at 70 psi (0.48 MPa, 4.8 bar) air pressure
C
at 40 psi (0.28 MPa, 2.8 bar) air pressure