308981 7
Installation
Fig. 2
9074A
H
J
A
C
D
K
L
M
N
Y
E
9075A
H
A
C
D
K
L
Y
9076A
A
E
K
P
R
S
T
U
V
Y
H
C
D
F
G
B
F
W
X
Z
04054
G
9074A
H
J
A
C
D
K
L
M
N
Y
E
9075A
H
A
C
D
K
L
Y
9076A
A
E
K
P
R
S
T
U
V
Y
H
C
D
F
G
B
F
W
X
Z
04054
G
KEY
A
Pump
B
Bleed-type master air valve (required for
pump)
C
Electrically conductive air supply line
D
Air line quick disconnect
E
Master air valve (for accessories)
F
Air line filter
G
Pump air regulator
H
Fluid drain valve (required)
J
Fluid regulator (optional)
K
Electrically conductive fluid supply hose
L
Fluid suction line
M
Underground storage tank
N
Wall mounting bracket
Y
Ground wire (required; see page 8 for
installation instructions)
ABOVE-GROUND TRANSFER INSTALLATION
55-GALLON BUNG PUMP INSTALLATION
KEY
A
Pump
C
Electrically conductive air supply line
D
Air line quick disconnect
H
Fluid drain valve (required)
K
Electrically conductive fluid supply hose
L
Fluid suction line
Y
Ground wire (required; see page 8 for
installation instructions)
AIR SPRAY INSTALLATION
KEY
A
Pump
C
Electrically conductive air line to pump
E
Gun air line shutoff valve
F
Air line filter
G
Gun air regulator
H
Fluid drain valve (required)
K
Electrically conductive fluid supply hose
P
Circulating valve
R
Electrically conductive air line to gun
S
Air spray gun
T
Electrically conductive fluid return line
U
5-gallon pail
V
Agitator
Y
Ground wire (required; see page 8 for installation
instructions)
VENTING EXHAUST AIR
KEY
W Muffler
X
Electrically Conductive Air Exhaust Hose
Z
Container for Remote Air Exhaust
All wetted and non-wetted pump parts must be