308981 9
Installation
Changing the Orientation of the Fluid Inlet
and Outlet Ports (Husky 515)
You can change the orientation of the fluid inlet and out-
let ports by repositioning the manifolds. For Husky 515,
see
Fig. 4
. For Husky 716, see
Fig. 5
.
1.
Relieve the pressure. See
Pressure
Relief Procedure
on page 10.
2.
Remove the four manifold nuts (109) or bolts (105).
3.
Turn the manifold to the desired position, reinstall
the nuts or bolts, and torque to 80 to 90 in-lb (9 to 10
NSm). See
Torque Sequence
, page 29.
NOTE:
Make sure all manifold o-rings are posi-
tioned correctly before you fasten the manifold.
Manifold o-rings (139) are shown in
Fig. 7
and
Fig.
8
.
NOTE:
Pumps with duckbill check valves are shipped
with the inlet manifold on top and the outlet manifold on
the bottom. See page 14 for details.
Fig. 4
f
Fig. 5
1
1
109
9065A
1
109
Torque to 80 to 90 in-lb (9 to 10 NSm). See
Torque
Sequence
, page 29.
outlet
inlet
1
1
105
9071A
1
105
Torque to 80 to 90 in-lb (9 to 10 NSm). See
Torque
Sequence
, page 29.
outlet