Technical Data
Fluid System Max. Working Pressure . . . . . . .
1500 psi (10.4 MPa, 103 bar)
Power Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
110/120 volt, 60 Hz
Main Supply Voltage Fluctuations . . . . . . . . . . .
Not to 10% of the nominal voltage
Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.40 amp
Units of Measurement
Totalizing . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dispensing . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gallons/Liters to 19999
0.01 increments up to 199.99 Pints, Quarts, Gallons, or Liters
Power Supply Cord . . . . . . . . . . . . . . . . . . . . . . .
7.5 ft (2.3 m), 18 AWG,3 conductor, molded vinyl plugs, 125 Vac,
10 amps
Control Power Output . . . . . . . . . . . . . . . . . . . . .
24 Vdc nominal at 0.60 amp maximum to any (1) fluid valve and
any (1) air valve simultaneously
Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . .
Lithium, 3.6 volt, 1.0 amp hour capacity (not replaceable)
Internal Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5 amp, 250 volt, non-serviceable
Operating Temperature Range* . . . . . . . . . . . .
+41 to 104
_
F (5 to 40
_
C)
Storage Temperature Range . . . . . . . . . . . . . . .
–20 to +150
_
F (–28 to + 65
_
C)
Maximum Relative Humidity . . . . . . . . . . . . . . .
80% for temperatures up to 88
_
F (31
_
C), decreasing linearly to
50% relative humidity at 104
_
F (40
_
C)
Installation Category . . . . . . . . . . . . . . . . . . . . . .
II
, indoor use only
Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Up to 6562 ft (2000 m)
Pollution Degree . . . . . . . . . . . . . . . . . . . . . . . . .
2
Control Dimensions
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 in. (203 mm)
10 in. (245 mm)
4 in. (102 mm)
4.5 lb (2.0 kg)
*
If the control is operated at higher ambient temperatures, periods of no flow must be more frequent and longer