m908 User Manual, Rev. G
13
Dimensions
ACU, RCU, and PSU dimension can be found in the m908 System Specifications document
https://gracedesign.com/support-documents/
Page 130 of 135
HOT
GND
TIP
SLEEVE
Normally open switch
To m908 ACU Remote Talkback Jack
Illustration 116: Remote Talkback Switch Wiring
TALLY
TALKBACK CONTROL
GND
1/4" TRS PLUG
TIP
SLEEVE
LED
Normally open switch
To m908 ACU Remote Talkback Jack
RING
Illustration 117: Remote Talkback Switch with LED Tally
1
2
3
SHIELD
HOT
GROUND
Talkback Balanced Output XLR
Illustration 118: Talkback Out Unbalanced Wiring