6.
Carrier Specific Information
Each cellular provider uses a different PRI file that needs to be programmed into the modem
for the modem to register properly on their cellular network and connect. These PRI files are
typically programmed into the modem by the manufacturer of the RF module. The following
sections list different carriers and the requirements for activating modems on their
networks. Cellular providers will (where applicable) supply username and password formats
for making EVDO calls. GPS Logic modems support the service provisioning features called
Over-the-Air Service Provisioning (OTASP) and Over-the-Air Parameter Administration
(OTAPA). OTASP occurs when a user initiates a call to the service provider. No further
commands are (typically) required to provision the modem. For example, a user with a new
modem/phone without service programming data can call the service provider's special
OTASP number to have the device programmed without physically taking it to the service
provider. OTAPA occurs when the network initiates a call to the modem and programs it
without any user intervention. OTAPA is typically used when the service provider decides to
update information on many cellular devices at the same time.
Note:
Logic-5000 radio modems are carrier specific, you must specify the carrier you
will be using when ordering. A unit purchased for one carrier cannot be activated
on any other carrier.
Note:
Generally, you will not be able to provision a device if you are not in your home
network area. You will also need to make sure that you have sufficient signal
strength to perform provisioning.
6.1.
Verizon Wireless
Note:
Before starting the OTA process, ensure that you have a strong enough signal for
cellular communication
When you activate a contract with Verizon, Verizon will assign a 10 digit MDN/MIN number
to your module’s ESN. When this is done, you are ready to OTA the module. Verizon
activation is done by submitting an OTA command of *22899 to the Verizon network. This
command is entered by default into the OTA command box on the “WAN Cellular Page”. It
should not be necessary to modify this command, simply select OTASP, click “Submit” and
allow the activation to complete. This process may take several minutes. This command is
also used to update the PRL file. When the OTA is complete, the MDN provided by Verizon
should be displayed on the home page.
6.2.
Bell Mobility
Activation on the Bell mobility network requires manual entry of the MDN, MIN and Unlock
code. Bell will provide these numbers when you initiate your data contract with them. In
most cases, the MDN and MIN will be the same number. On the WAN Cellular page, enter
the MDN, MIN and Unlock code and click “Submit”. The activation process will occur
automatically once the parameters are entered. This process may take a few minutes and
you may need to reset the device to have full network access.
Page 57 of 59