Software / Parameter Settings
English, Revision 06, Date: 12.07.2011
20
4.1.2
Parameter Settings
The following parameters are necessary. Those settings are applied in the CANopen®
mode as well as at the serial interface always in the first 10 seconds after switching-on.
If you use another port than
COM1
but want to use HyperTerminal you have to switch
the port as follows:
1.
In the menu
Data
choose the submenu
Properties
(or click on the icon). The
following window pops up:
:
2.
Choose in the submenu
Connections
the corresponding port and confirm
with
OK.
Save the altered parameters when receiving the corresponding mes-
sage while closing the program.
4.2
Using the configuration program
The terminal (PC with Hyperterm program) is to be connected to the interpreter via the
corresponding socket.
-
CANopen®: The interface parameters are: 38400,8,e,1 and VT52 terminal emula-
tion. After entering
the monitor will start.
Terminal settings configuration program (see section 4.2)
Baud rate
38400 baud
Terminal emulation
VT52
Parity
even
Data bits
8
Stop bits
1
Handshake
none
PC interface (Port)
COM1
may vary on some PCs (see below)
Table 5
Terminal settings for the configuration program