Appendix
8.1
Adjustable Functions and Parameters
Setting saved with *SAV n:
Default setting after
RESET *RST:
Expla-
nation in
Chapter
on Page
Manual setting or via interface
n=1
...
10
n=11
...
255
Setting Command Significance / Effect
Manual
IEE
E 488
RS 232C
Addr
n
Set device address for RS 232 or IEEE 488 (interface configuration)
X
ADDR
ESS
n
n:
0;1; ... ; 31 (device addresses)
X
unchanged
bAUd
txt
Set transmission speed (interface configuration)
X
unchanged
txt:
50; 75; 150; ... ; 4800; 9600; 19.2t (transmission speed in bits per sec.)
CAL
Start “CAL” routine in accordance with chapter 7 of the operating instructions
X
unchanged
CAL
txt, v
X
X
dbit
txt
Set number of data bits (interface configuration)
X
unchanged
txt:
7; 8
dly
v
Output off delay for OCP (setup)
X
X
DE
LAY
v
v:
0; 0.1; ... 99.9 (delay time in seconds)
X
X
X
0.00 s
DI
SPLAY
txt
Activate / deactivate digital displays
X
X
ON
txt:
off, on
IL
IM
v
Current setting limit (setup)
0
v
I
nom
X
X
X
X
I
nom
v:
12.00
(example: 12.00 A)
IS
ET
v
Current setpoint
0
v
ILIM
X
X
X
X
X 0.000
v:
10.75
(example: 10.75 A)
OC
P
txt
Response selection for current limiting (overcurrent protection), (setup)
X
X
X
X
oFF
txt:
oFF, on
(current regulation / output off after expiration of delay time dLY)
Output (key)
Activate / deactivate the output
X
oFF
OU
TPUT
txt
txt:
OFF, ON
X
X
X
OVP
v
Overvoltage protection trigger value (setup)
0
v
1.25 x U
nom
X
X
1.25 x U
nom
OVS
ET
v
v:
32.5
(example: 32.5 V)
X
X
X
Pbit
txt
Set parity bit (interface configuration)
X
unchanged
txt:
nonE
no parity bit
ZEro
always 0
EVEn
even numbered
odd
odd numbered
onE
always 1
pon
txt
Device setting selection after power-up (setup)
X
POW
ER_ON
txt
txt:
rSt
(default settings)
X
X
unchanged
SbY
(last used settings, output deactivated)
rcL
(last used settings)
rEP
n
Repetition, number of sequence repetitions (sequence)
X
X
cont or 0 =
RE
PETITION
n
n:
1; ... ; 255
X
X
X
0
rnd
txt
Round off the displayed measured value (setup)
X
unchanged
txt:
0; –1; –2 (no rounding, round by one or two decimal places)
Sbit
txt
Set number of stop bits (interface configuration)
X
unchanged
txt:
1; 2
SEq
txt
Sequence, automatic memory recall
X
on
1)
SEQ
UENCE
txt
txt:
Go (start); (off, on (close/end, open))
running SEQ, “stop”
Hold (pause/suspend); cont (resume); strt, step, stop (step-by-step control)
X
X
SiG1
txt
Signal output 1 (analog interface)
X
unchanged
SiG2
txt
Signal output 2 (analog interface)
X
Si
g1_Sig2
txt1, txt2 txt:
oFF
SIG inactive (passive high)
X
X
on
out
ModE
SEq
SSEt
U_Lo
U_Hi
I_Lo
I_Hi
SIG active (active low)
Signal level depends upon the output’s activation status
OUTPUT on: passive high
OUTPUT OFF: active low
Signal level depends upon momentary control mode
OFF or CV: passive high
CC or OL: active low
Signal level depends upon activated sequence run
Sequence being executed: active low
Signal level depends upon SSET switching function (
SEQUENCE)
OFF: passive high
ON: active low
Compare measured voltage value with USET from sequence memory location 254.
Measured voltage value
reference value: passive high
Measured voltage value < reference value: active low
Compare measured voltage value with USET from sequence memory location 255.
Measured voltage value
reference value: passive high
Measured voltage value > reference value: active low
Compare measured current value with ISET from sequence memory location 254.
Measured current value
reference value: passive high
Measured current value < reference value: active low
Compare measured current value with ISET from sequence memory location 255.
Measured current value
reference value: passive high
Measured current value > reference value: active low