34
GMC-I Messtechnik GmbH
SEq – Sequence, Automatic Memory Recall
Functions
•
Controls automatic and step-by-step sequence runs.
Setting Parameter
☞
Strt: select step-by-step control
, jump to start address (status:
RDY
HOLD), execute command with the
<ENTER>
key.
☞
GO: select SEQUENCE
, jump to start address and start (status:
RDY
RUN), execute command with the
<ENTER>
key.
Additional Setting Parameters
with running or suspended sequence, and in step-by-step mode
☞
hold: SEQUENCE
runs stops at current address (status: RUN
HOLD), execute command with the
<ENTER>
key.
☞
cont: SEQUENCE
is resumed at next address (status: HOLD
RUN), execute command with the
<ENTER>
key.
☞
StEP:
execute next memory location and start (status: HOLD
HOLD), execute command with the
<ENTER>
key.
☞
StoP: SEQUENCE
is stopped and jumps to stop address (status:
RUN
RDY or HOLD
RDY), execute command with the
<ENTER>
key.
Settings
(see sequence settings and execution on page 35)
☞
Procedure
for selecting
SEq, (
see also chapter 4.7
!
The
SEq
display appears in the window for the
SEq
function.
☞
Press the
<ENTER>
key in order to switch to the
SEQUENCE
menu.
☞
Repeatedly press the
<FUNCTION>
key (max. 6 times) until the
SEq Go
function appears.
Figure 4.7.3 i
Preparing a
SEQUENCE
☞
Acknowledge the sequence with the
<ENTER> key.
Figure 4.7.3 j
Preparing for
Step-by-Step Control
!
The first valid memory location is now executed, and the
values saved to this location (
Uset
,
Iset
and
SSEt
) are read out
to the power output and the signal output.
The LOCKED/SEQ LED blinks slowly
.
Figure 4.7.3 k
Preparing for Automatic
SEQUENCE
Control
!
In this case, all memory locations are executed, one after the
other, from the start address to the stop address, and the
respective values saved to each location (
Uset
,
Iset
,
tdef/tset
and
SSEt
) are read out to the power output and the signal
output.
The LOCKED/SEQ LED blinks rapidly.
.
Note
!
Automatic and step-by-step sequence control (external trigger
or setting command) are
not interlocked
.
!
After the SEQUENCE run has been started, various
error
messages
may appear for a period of approximately 1 second
(see also page 36 and the appendix).
!
If an error occurs during execution of the
sequence
, bit 5 SEQE
(SEQuence Error) is set in event register B (ERB).
☞
The procedure shown in Figure 4.7.3 l must be used for
setting up and starting
sequences
for
SSP KONSTANTERs
with
software version < REL. 003.
In this case,
sequences
can only be set up and started if the
SEQ ON
test parameter has been selected after entering the
SEq
menu.
Figure 4.7.3 l
SEQUENCE preparation with software
version < REL. 003
Select the text parameter
from an options loop
From the SEq function group
*
ENTER
CE/LOCAL
FUNCTION
Continue in the SEq function group
ENTER
FUNCTION
+
Jump to the start address or the
first address with valid contents
Step-by-step control
LOCKED/SEQ
LOCKED/SEQ
Continue in the SEq function group
ENTER
FUNCTION
+
Sequence running
LOCKED/SEQ
LOCKED/SEQ
Select the
from an options loop
From the SEq function group
*
ENTER
CE/LOCAL
FUNCTION
ENTER
ENTER
text parameter
Summary of Contents for SSP 120 Series
Page 2: ...2 GMC I Messtechnik GmbH ...