installing the goslyn™ to the ovens

 

 
 

1.

 

Run   1   ½”   copper   from   the   top   ovens   to   the   inlet   of   the   goslyn   (You   will   need   a   2”   to   1   ½”   

reducer   for   the   inlet.   

   

2.

 

Be   sure   to   brass   unions   on   the   stub   out   from   the   oven   to   the   wall   to   allow   employees   to   

move   the   ovens   for   cleaning.      There   needs   to   be   a   quick   disconnect   when   you   are   

plumbing   from   the   wall   to   the   goslyn.   

   

3.

 

Run   1   ½”   copper   from   the   lower   ovens   to   the   1   ½”   hole   located   on   the   lower   section   of   

the   lower   oven   pump   tank.      Use   disconnects   after   you   leave   each   oven   and   before   

entering   the   lower   oven   pump   tank.   

   
4.

 

Use   ¾”   copper   to   come   out   of   the   top   of   the   pump   and   connect   it   to   the   1   ½”   line   

running   from   the   top   ovens   (You   will   need   a   1   ½”   to   ¾”   reducing   T).      Be   sure   to   put   a   ¾”   

union   on   this   line   just   above   pump   outlet   in   case   the   pump   needs   to   be   replaced   at   a   

later   date.   

   

5.

 

Run   a   1   1/2”   line   from   the   outlet   of   the   goslyn™   to   the   floor   drain.   

   

6.

 

Run   a   1   1/2”   line   from   the   overflow   located   on   the   top   portion   of   the   lower   oven   drain   

pump.   

   

 

 

Summary of Contents for CDSTD-10

Page 1: ...ROTISSERIE OVEN PROGRAM GUIDE Goslyn LP 1904 University Business Dr 310 McKinney TX 75071 Phone 888 648 5040 Fax 214 618 3765 WWW GOSLYN COM DEC 2013 ...

Page 2: ...quipment 6 scope of work 7 materials list 11 goslyn and components installation instructions 12 goslyn startup procedures goslyn maintenance 14 15 troubleshooting 16 goslyn specification sheets 18 goslyn model GOS40 grease recovery separator 19 goslyn model LDPS 10 grease low drain pump system 20 goslyn model CDSTD 10 grease stand 21 ...

Page 3: ...d requires the grease interceptor to be pumped out frequently The goslyn is an Automatic Grease Recovery Device It separates and captures the oil chicken fat from the water Clean water is discharged through the goslyn outlet into the floor drain and the recovered oil is discharged through an oil valve into a cassette top picture or in situations where there is a large quantity of recovered oil it ...

Page 4: ...the floor drain There is a copper pipe connecting the goslyn s silt valve to the floor drain which is used to flush any fine particles that make it through the strainer basket The recovered oil is discharged from the goslyn s oil into a cassette located on the side of the goslyn or if preferred a larger bucket can be placed below the goslyn The employees will take the oil to the oil collection tan...

Page 5: ...ow Drain Pump System LDPS 10 hung on side of goslyn Grease Stand very low to floor used to pump effluent from bottom rotisserie ovens up into GOS40 goslyn Control Panel hangs on the side of the Low Drain Pump System used to power and control the sensors pumps for the Low Drain Pump System 120 volt 20 amp duplex outlet power supply located next to the goslyn Power must be available and on 24 hours ...

Page 6: ...e Deli next to the Rotisserie Ovens To the right or left of the GOS40 will be the first double stack Rotisserie Oven The second set of ovens will be to the right or left of the first double stack of Rotisserie Ovens Deli Area Rotisserie Ovens goslyn Grease Stand Low Drain Pump System for Bottom Ovens ...

Page 7: ...e pipe that was run in step three 1 copper 5 When plumbing rotisseries and prior to the GOS 40 and LDPS 10 be sure to use Brass Unions as couplers to allow employees to move ovens for easy cleaning 6 Connect a 3 4 inch union above the outlet of the Low Drain Pump System LDPS 10 reservoir pump to allow employees to disconnect the goslyn from the Grease Stand Run a copper pipe to the 1 pipe from upp...

Page 8: ...overy Program Page 8 Plumbing shown for the Low Drain Pump System The Overflow is plumbed to the floor drain Plumbing shown from the 2nd Bottom Rotisserie Oven connected to the drain from the 1st Top Rotisserie Oven ...

Page 9: ...Goslyn Oil Recovery Program Page 9 Plumbing shown for the Top Oven coming across the back wall and then into the Goslyn with the LDPS tie in ...

Page 10: ...Goslyn Oil Recovery Program Page 10 Front of Goslyn with silt valve plumbed using street elbow ...

Page 11: ...k disconnects 6 2 to 1 1 2 copper reducer 1 1 1 2 male fitting for effluent line into pump tank 1 copper pipe 5 copper 90 s 1 1 1 2 x 1 1 2 x 3 4 copper T 1 3 4 copper union 1 3 4 male fitting for pump outlet 1 1 1 2 to 3 4 copper reducer 1 2 copper male fitting for goslyn inlet and outlet 2 1 5 8 uni strut clamps 6 NOTE Quantities are based on two double stacked rotisserie ovens ...

Page 12: ...he unit DO NOT PLUG IN THE HEATER UNTIL THE UNIT IS FULL OF WATER 6 Remove the lid and make sure that the rubber O rings are in place on both oil valve housings inside the unit Lubricate the rings with oil or grease 7 Place the 1 25 diameter plastic ball into the oil valve housing located on the right side 8 Install the shorter oil valve into the housing on the right side above the ball with the s...

Page 13: ...pper from the lower ovens to the 1 hole located on the lower section of the lower oven pump tank Use disconnects after you leave each oven and before entering the lower oven pump tank 4 Use copper to come out of the top of the pump and connect it to the 1 line running from the top ovens You will need a 1 to reducing T Be sure to put a union on this line just above pump outlet in case the pump need...

Page 14: ...as the control box located on the side LDPS 10 The red light on the heater should be on at all times showing power is getting to the heater 4 Ensure the sensor on the Low Drain Pump System is green 5 Turn on the water on the lower rotisserie ovens and ensure that when the low drain tank fills up the sensor light turns yellow and starts the pump 6 Make sure the oil cassette is on the side of the go...

Page 15: ...o the 3 compartment sink and rinse off remaining grease Replace strainer basket in goslyn and close the lid 2 Open the two small hatches on the lid Use the bottle brush to clean the oil valve at the end of the day 3 Hold open the silt valve for 5 seconds twice a day to purge out any settled silts Be sure that you are running water through the system while performing the operation to prevent the sy...

Page 16: ...and pouring in water Make sure you unplug the Control Box before priming the pump If priming pump does not work contact your plumber to ensure that no debris is stuck in the pump goslyn Oil Recovery Device Unit is surcharging at the inlet o The strainer basket needs to be emptied o Open the silt valve and flush out the silts for 10 to 15 seconds with the oven water turned on Effluent is collecting...

Page 17: ...s starting to develop foul odor o Always empty the strainer basket at the end of the night after all ovens are turned off to eliminate solids from remaining in system o Make sure the silt valve is flushed on a daily basis per daily maintenance requirements No oil is coming out of the oil valve and or Oil is going out of the goslyn outlet o Clean oil valve with supplied bottle brush o Make sure the...

Page 18: ...consist of the various specification sheets associated with the Goslyn Oil Recovery System and the specific pieces of equipment that comprise it Those specification sheets are Goslyn MODEL GOS 40 Grease Recovery Separator Goslyn Grease Low Drain Pump System Goslyn Grease Stand for GOS 40 ...