S SERIES
OM--05096
OPERATION
PAGE C -- 1
OPERATION --- SECTION C
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and
decals attached to the pump.
PUMP OPERATION
Do not operate this pump where explo-
sive vapors or flammable material exist.
Death or serious injury will result.
This pump is designed to handle dirty
water that does not contain large en-
trained solids. It is not designed to
pump volatile, flammable or corrosive
materials. Do not attempt to pump any
liquids which may damage the pump or
endanger personnel as a result of pump
failure.
Install the pump and piping as described in
IN-
STALLATION
, Section B.
Manual Operation
The pump is provided with a 30-foot (3 m) power
cable.
Never
splice the power cable due to safety
and warranty considerations.
Never attempt to alter the length or re-
pair any power cable with a splice. The
pump motor and cable must be com-
pletely waterproof. Damage to the pump
or personal injury may result from alter-
ations.
Always keep the plug end dry.
Figure 1. Always Keep Plug End Dry
For manual operation, simply plug the power cable
into any 115 volt
grounded
receptacle. It is strong-
ly recommended that a Ground Fault Interrupter
(GFI) type receptacle (or equivalent) be used (see
Figure 2).
Always use a three-prong grounded re-
ceptacle. It is strongly recommended
that a Ground Fault Interrupter (GFI)
type receptacle (or equivalent) be used.
Figure 2. Always Use a Grounded Receptacle
Automatic Operation
A float switch assembly is available as an option
from the factory to provide for automatic operation.
Observe the following instructions for automatic
operation.
1. Attach the plastic tie on the float switch power
cable to the standpipe in the sump at the ap-
proximate desired liquid level.
Do not
allow