OM--05096
S SERIES
PAGE B -- 1
INSTALLATION
INSTALLATION --- SECTION B
Review all SAFETY information in Section A.
Do not operate this pump where explo-
sive vapors or flammable material exist.
Death or serious injury will result.
This section only summarizes recommended in-
stallation practices for the pump. If there are ques-
tions concerning your specific application, contact
your local distributor or the Gorman-Rupp Com-
pany.
Pumps and related equipment must be in-
stalled and operated according to all na-
tional, local and industry standards.
PREINSTALLATION INSPECTION
Before installation, inspect the pump for damage
which may have occurred during shipment. Check
as follows:
a. Inspect the pump assembly for cracks, dents,
damaged threads, and other obvious dam-
age.
b. Check for and tighten loose attaching hard-
ware.
c. The pump is furnished with a 30-foot (9 meter)
long power cable. Inspect the cable for cuts or
damage.
d. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties
as indicated.
If anything appears to be abnormal, contact your
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy.
Do not
put the
pump into service until appropriate action has
been taken.
Lubrication
The shaft seal and bearings in this pump are fully
lubricated from the factory. No additional lubrica-
tion is required.
PUMP INSTALLATION
Pump Dimensions
The pump is provided with a suction strainer to pre-
vent large solids from clogging the impeller. See
Figure 1 for the approximate physical dimensions
of the pump.