EN
35
Setting the TIMER mode
In the TIMER operating mode, you can set the times when the heat pump will start and stop. For each timer combination you
can set up to three time periods in which the heat pump will not heat the water
a) Setting the timer combinations
• Hold field no.
11
for a while (fields
7
and
11
start to flash).
• By pressing fields
+
or
–
choose among three timer modes of operation:
- Timer mode of operation of the heat pump for the entire week (numbers 1-7 flash in field no.
7
),
- Timer mode of operation of the heat pump for Monday to Friday and Saturday to Sunday (numbers 1-5 and then 6 and 7
flash in field no.
7
),
- Timer mode of operation of the heat pump for each day at a time (individual numbers 1-7 flash in field no.
7
). Press field
+
or
–
to select each day of the week.
• To set the time, press field no.
12
.
• On the field no.
5
, the text 1OF appears and field no.
12
starts to blink.
• By pressing fields
+
or
–
set the time of shutdown.
• Press field no.
12
again.
• On the field no.
5
, the text 1ON appears and field no.
12
starts to blink.
• By pressing fields
+
or
–
set the time of start-up.
• By pressing field no.
12
again, you can use the above procedure to set the second and third period.
• If you do not want to set the second and third periods, confirm the setting by pressing field no.
11
or wait for field no.
12
to
stop flashing and the setting to be saved automatically.
• To set the second and third periods, set the start and end of periods 2 and 3 and confirm the setting following the procedure
described above by pressing field no.
11
or wait for field no.
12
to stop flashing and the setting to be saved automatically.
• To set the timer operating mode "for each day of the week" or "for the period from Monday to Friday and from Saturday to
Sunday", set all 3 time periods following the procedure described above.
b) Activation, deactivation of timer
• By pressing field no.
11
, you can activate the set timer mode.
• The heat pump heats the water in the ON periods (to the set temperature) and in the OFF periods, it does not heat the water.
• By pressing field no.
11
again, you can deactivate the set time mode of operation.
Figure 18:
Time period
Maintenance level access
• By pressing field no.
4
, you can activate the maintenance mode
(Figure 16)
.
• A display menu with an inscription “code” in the filed
CLOCK
appears. Enter the maintenance code (fields FN1, FN2, FN3,
FN4, FN5 in FN6 for numbers 1, 2, 3, 4, 5, 6).
Figure 19:
Fields display
• If you do not press any field for 10 s, the programme returns to the start menu.
• If the code is incorrect, the programme returns to previous operation.
• If the code is correct, the first parameter appears on the display. The number on the right is the serial number of the
parameter and the field on the left is intended for its value.
• The first parameter
:00
is a version of a software code and serves information purposes only.
• By pressing the right number (Field
CLOCK
in
Figure 19
) you proceed to the next parameter.