34
EN
Setting the clock and day of the week
• Hold field no.
12
, until field no.
7
shows a flashing number of the day of the week.
• By pressing
+
or
–
you can set the number of the day of the week (1 – Monday, …, 7 – Sunday).
• Press field no.
12
again (flashing hour setting is displayed).
• By pressing
+
or
–
set the hour (by holding
+
or
–
you can speed up the setting).
• Press field no.
12
again.
• Flashing minute setting is displayed.
• By pressing
+
or
–
set the minutes (by holding
+
or
–
you can speed up the setting).
• The setting is stored when you press field no.
12
, or when the field stops flashing.
Figure 17:
Temperature settings, switch on “ TURBO” and “ HOT” mode
Setting the temperature
• Press field no.
5
(the set temperature starts blinking).
• By pressing
+
or
–
you can change the temperature setting from 10 °C to 75 °C, preset to economic temperature of 55 °C.
• The setting is stored by pressing field no.
5
again, or when field no.
5
stops flashing. After a few seconds, the display shows
the actual temperature.
The set temperature should suffice actual needs. Recommended temperature settings are between
45 and 55 °C. Higher settings are not advisable because above these temperatures, electric heaters start and the
system efficiency is reduced.
• In case of power failure, the last stored value is restored.
Switching on the "TURBO" mode
• If you need more warm water than the heat pump can heat up in a short period of time, press field no.
13
(switches on the
"TURBO" mode). The heat pump and heater work simultaneously. The screen shows symbols no.
14
,
16
and
20
. When the
temperature reaches 55 °C the heat pump returns to the mode used before the "TURBO" mode.
Switching on the "HOT" mode
• If you want to heat the water to the maximum temperature of 75 °C, press field no.
15
. The heat pump will heat water to
55 °C. The screen displays symbols no.
16
in
20
. When the temperature in the boiler reaches 55 °C the electric heater turns
on to heat the temperature up to 75 °C. The screen displays the symbol no.
14
. When the temperature reaches 75 °C the
heat pump returns to the mode used before the "HOT" mode.
Display of the quantity of water in the heat pump
The display shows the symbol
18
:
•
- no warm water
•
- low quantity of warm water
•
- high quantity of warm water
Setting the vacation mode
In the vacation mode, you can set the number of days (maximally 100), when the heat pump shall maintain the minimal
temperature of water (approximately 10 °C).
• Hold field no.
6
for a while (fields
5
and
6
start to flash).
• By pressing fields
+
or
–
you can set the number of vacation days shown in field no. 5.
• By pressing field no.
6
again, or when field no.
6
stops flashing, the set number of days is stored.
• If you set the value to 0, then the heat pump will resume its normal operating mode after confirming the setting, and
illumination of field no.
6
will turn off.
• After the set number of days has elapsed, the heat pump returns to the normal mode and illumination of field no.
6