Coupler Dimensions

This is a dimensional drawing of

the 04A035 Coupler.

All dimensions are in inches (with

metric equivalents in parentheses).

These couplers come mounted to

an antenna, but are available for

sale separately.  Cables are sold

separately - 8' (2.44m) is standard,

with other lengths available on

request.

2.20" (55.9mm)

3.20"

(81.3mm)

3.10"

(78.7mm)

1.25"

(31.75mm)

1.00"

(25.4mm)

0.40" (10.2mm)

1.25" (31.8mm)

Separate Cable
w/Locking Connector

Front View

End View

1.10"

(27.9mm)

Side View

Mounting Holes

.190" (4.83mm) dia.

For RC4000 Series Reel Controls only

G

or o

d n

Brookfield, Connecticut    USA     06804-2494

E

ngineering

Corp

.

04A035

Antenna Coupler

RC4000/RC4000M

Lot #

ANTENNA SIDE

Antenna Selection

Providing the proper antenna for your application is a crucial
part of making the RC4000 Reel Control system perform to its
best abilities.  Fortunately, this process has been made easy -
due in large part to the introduction of our line of modular
antennas.

These modular antennas come with an integrated coupler, and
are designed to be quickly and easily swapped, by unplugging
the locking cable connector.  This allows for rapid replacement,
if an antenna is physically damaged, and for quick and easy
setups, in applications where a variety of material sizes are
processed by the same equipment.  Process down time is kept
to a minimum, allowing you to maximize productivity.

Once you’ve determined the size of the material you wish to
control, just look at the chart on the next page to select the
proper antenna for your application.  Under the heading, Use to
Control, find the size range of the material you need to control.
There are two sizes of “V” antennas for each material size, one
12" in length and one 18" in length.

For applications where the process speed is slow or where the
motor and gear ratio are well matched to the process, a 12"
antenna will provide all the control you need, with the added
bonus of being very compact.  Where the process runs at fast
speeds or where dynamic mismatches exist in the application,
you will want to choose an 18" antenna.  This provides more
control range and enhances the ability of the RC4000 to com-
pensate for any mismatches in the application.

In applications where wide strips (6" or more in width) are to
be reeled, it is possible to use a flat-plate antenna.  These types
of antennas should be positioned directly above or below the
lowest point of the material loop, with the long dimension of
the antenna perpendicular to the direction of travel.

RC4000 Series Antenna Selection and Specifications

4

www.gordoneng.com

1.800.315.9233

04A049 Cable

8' (2.44m) Standard length
other lengths quoted on request

sold separately

Summary of Contents for RC4000 Series

Page 1: ...Series Reel Control Systems http www gordoneng com revision date 05 17 01 Owner s Manual Installation Operation and Applications R e e l o r T ake Up Dereel or Payoff 1 800 315 9233 call toll free in...

Page 2: ...This product will be repaired or replaced for five years from the date of purchase if it fails to perform to published specifications The product must be used in accordance with the specified manufac...

Page 3: ...ions RC4000 Reel Control page 2 RC4000M Reel Control page 3 ii Contents 8 9 RC4000 Installation Input Output Wiring page 9 Interlocks page 9 Shock Mounts page 9 4 6 Antenna Selection 7 Speed Reduction...

Page 4: ......

Page 5: ...ty motor controllers while the RC4000M has a self contained motor controller The control unit determines the load and status of the antenna assembly and establishes a tuned RF sensing field around the...

Page 6: ...ted by dirt grease vibration etc temperature 0 F 130 F humidity 0 95 R H RC4000 Specifications 2 www gordoneng com 1 800 315 9233 Keypad Controls SELECT in setup mode push to select reel or dereel mod...

Page 7: ...dia 21 84mm B Hole C Coupler 50 dia 12 7mm B C Top View Front View base only Side View 4 Mounting Holes clearance holes for 250 6mm bolt 7 30 185 42mm Fuse Holder RC4000M Specifications www gordoneng...

Page 8: ...f material sizes are processed by the same equipment Process down time is kept to a minimum allowing you to maximize productivity Once you ve determined the size of the material you wish to control ju...

Page 9: ...ip 1 3 strip 3 5 strip 3 5 strip 4 7 strip 4 7 strip 6 or wider strip Part Number 04A073 04A074 04A091 04A092 04A067 04A068 04A069 04A071 04A070 04A072 04A088 Flat L e n g t h o f V Antenna idth W Cab...

Page 10: ...r 2 4 meters and optional lengths of fifteen feet 15 or 4 6 meters and twenty five feet 25 or 7 62 meters are readily available Mount your antenna so the material runs through the middle of the V and...

Page 11: ...sed for example for a motor rated at 1725 RPM calculate the ratio for 1500 RPM Sample Calculation 1500 3 14 6 1000 Where S 1500 RPM F 1000 units of measure min d 6 units of measure Note the Speed S at...

Page 12: ...uration with the Reel mode selected For specifics on mounting the antenna coupler assembly refer to page 6 In dereel applications if the material breaks it may be pulled from the sensing field by the...

Page 13: ...o a relay contact that closes when reel motor stop is required The Auto LED blinks to indicate the interlock is asserted and since the unit is temporarily in SETUP mode the JOG feature can be used Whe...

Page 14: ...antenna Limit lights lit when loop height exceeds control range Run light on when motor function is active AUTO or JOG Auto light on when unit is in the Auto mode reel motor is controlled by antenna i...

Page 15: ...is reached then press ENTER The ADJUST Up and Down keys allow the speed to be fine tuned Pressing any other key than ADJUST Up or Down disables this function AUTO Ensure that your line is operational...

Page 16: ...specifics on mounting the antenna coupler assembly refer to page 6 In dereel applications if the material breaks it may be pulled from the sensing field by the machine processing the material This wi...

Page 17: ...nnect the motor field wires to terminals 6 and 7 once again be sure to observe the polarity of the terminals and your field wires Modification 04A060 must be installed on any RC4000M Reel Control that...

Page 18: ...antenna Limit lights lit when loop height exceeds control range Run light on when motor function is active AUTO or JOG Auto light on when unit is in the Auto mode reel motor is controlled by antenna...

Page 19: ...is reached then press ENTER The ADJUST Up and Down keys allow the speed to be fine tuned Pressing any other key than ADJUST Up or Down disables this function AUTO Ensure that your line is operational...

Page 20: ...n problem We also make a full range of inductive ring sensors For price and delivery call our sales department or the regional distributor listed below Don t forget our Five Year Guarantee it comes wi...

Reviews: