![Gordon RC4000 Series Owner'S Manual Download Page 7](http://html1.mh-extra.com/html/gordon/rc4000-series/rc4000-series_owners-manual_2244911007.webp)
RC4000M Dimensions
This is a dimensional drawing of
the RC4000M enclosure.
All dimensions are in inches (with
metric equivalents in parentheses).
For mounting instructions and
specifics on shock mounts, please
see the Installation section of the
RC4000 User’s Manual.
Input Voltage
115/230 VAC; 50/60 Hz
Power Consumption
1200VA
Motors
directly drives DC shunt wound
or permanent magnet motors
up to 1/2 HP 90 volt armature
or 1 HP 180 volt armature
Interlocks
auto: allows on/off control of
the reel motor by processing
equipment - JOG active
shutoff: allows on/off control of
the reel motor by processing
equipment - JOG inactive
Enclosure
NEMA 12, industrial plastic
10.2" L x 7.8"W x 4.0"D
(259 mm x 199 mm x 102 mm)
Mounting
vertical or horizontal - to any
bulkhead, chassis or panel
Shipping Weight
6.0 lbs. (2.7 Kg)
Environment
unaffected by dirt, grease,
vibration, etc.
temperature:
0°F - 130°F
humidity:
0 - 95% R.H
8.71" (221.23mm)
9.49" (241.05mm)
4.13"
(104.9mm)
10.21" (259.33mm)
2.475"
(62.9mm)
3.00"
(76.2mm)
6.07"
(154.18mm)
7.82"
(198.63mm)
4.75"
(120.65mm)
4.03"
(102.4mm)
1.555"
(39.5mm)
1.75"
(44.45mm)
1.94"
(49.3mm)
1.75"
(44.45mm)
A
A
- Knockout &
.860"dia. (21.84mm)
B
- Hole
C
- Coupler
.50"dia. (12.7mm)
B
C
Top View
Front View - base only
Side View
4 Mounting Holes
clearance holes for
.250" (6mm) bolt
7.30" (185.42mm)
Fuse
Holder
RC4000M Specifications
www.gordoneng.com
1.800.315.9233
3
Keypad Controls
SELECT (in setup mode)
push to select reel or dereel mode,
antenna position, and high and low
limit relay activation.
ENTER (in setup mode)
push to lock in SELECT settings
TUNE (in setup mode)
push to tune system
JOG (in setup mode)
push and release to nudge motor
push and hold to run motor
AUTO/SETUP
push to toggle between setup and
auto modes
ADJUST Up /Down (in auto mode)
allow motor-on, realtime loop height
adjustment
Indicators
Bargraph: displays loop height
relative to antenna
Limit lights: lit when loop
height exceeds control range
Run light: on when motor function
is active - AUTO or JOG
Tune light: flashes when tuning is
required
on while unit is tuning
flashes with fault light on to indicate
antenna fault
Fault light: indicates a loss of
antenna or internal fault
Selection indicators: for reel / dereel,
antenna position, and high and low
limit relay activation, the indicators
flash to show they are available for
selection. Use the SELECT key to
step through the choices. Use the
ENTER key to set each choice.
Indicators stay lit to show how the
unit is configured.