![Gordon RC4000 Series Owner'S Manual Download Page 11](http://html1.mh-extra.com/html/gordon/rc4000-series/rc4000-series_owners-manual_2244911011.webp)
Checklist
Checklist
Since the feed-rate in most applications
requires much less than standard 1725 RPM DC
motor speed, you must connect a speed reducer
between the motor and the reel. You can use the
following formula to calculate gear ratios.
S ( 3 . 1 4 ) d
F
Where:
R
= step-down ratio between motor and reel
F
= maximum machine feed-rate (units of measure/min)
d
= reel hub diameter (units of measure)
S
= motor speed (RPM)
In order to allow some margin for feed-rate
increase, a motor speed (S) less than maximum
should be used; for example, for a motor rated at
1725 RPM, calculate the ratio for 1500 RPM.
Sample Calculation:
(1500)(3.14)(6)
1000
Where:
S
= 1500 RPM
F
= 1000 units of measure/min
d
= 6 units of measure
Note the Speed (S) at which your motor
is rated to operate here ( RPM)
and in the top line of the formula below.
Note your Reel Hub Diameter (d)
here (
units of measure
) and in the
top line of the formula below.
Note the Feed Rate (F) of your
machine here (
units of measure/min
)
and in the bottom line of the formula below.
(
) (3.14) (
)
( )
Note the Step Down Ratio (R) of
your machine below - round
your answer to the nearest
whole number.
R = : 1
S p e e d R e d u c t i o n
i s R e q u i re d f o r M o s t
A p p l i c a t i o n s
www.gordoneng.com
1.800.315.9233
7
Speed Reduction
R =
R =
= 28.2